background image

16

PRECAUTIONS, RESTRICTIONS AND WARNINGS

Transportation, storage and operation

This equipment must be transported and stored observing the following directions:

- Avoid falls and impacts;

- Keep it dry, do not expose it to rain, water drops or wet floor;

- Keep it away from water and direct sunlight, and in it original wrapping;

- Don’t move it over irregular surfaces, protect it from rain and observe the maximum stack quantity

specified in the packaging;

Environmental condition for transportation or storage:

- Room temperature range for transportation or storage -29ºC to +60ºC.

- Relative humidity range for transportation or storage 20% to 90%.

- Atmospheric pressure range 500hPa to 1060 hPa (375 mmHg to 795 mmHg).

Environmental condition for storage (among the operations):

- Room temperature range for storage -10ºC a +55ºC.

- Recommended room temperature range +15ºC a +30ºC.

- Relative humidity range for storage 30% a 75%.

- Atmospheric pressure range 700 hPa to 1060 hPa (525 mmHg to 795 mmHg).

Environmental operation condition:

- Room temperature range for funct10ºC to +40ºC.

- Recommended room temperature range +21ºC to +26ºC.

- Relative humidity range for functioning 30% to 75%.

- Atmospheric pressure range 700 hPa to 1060 hPa (525 mmHg to 795 mmHg).

- Operation altitude: ≤2000m.

Attention 

The Equipment maintains its condition of safety and efficacy, provided that it is maintained

(stored) as mentioned in this instruction of use. Thus, the equipment will not lose or alter

its physical and dimensional features. 

Sensitivity to environmental conditions in normal situations of use

The  equipment  has  been  planned  not  to  be  sensitive  to  interference  such  as  magnetic  fields, 

external electrical factors, electrostatic discharge, pressure or variance of pressure, provided that 

the equipment is installed, maintained, clean, preserved, transported and operated as per this 

instruction for use.

Precaution and warnings “during the installation” of the equipment

- This equipment can only be unpacked and installed by an Alliage authorized technician.

- Check that the socket in which the device will be connected has a ground connection. According to

the ABNT standard, this is essential for the safe operation of the system.

- Install the equipment in a place where it will not be damaged by the pressure, temperature, humidity,

direct sunlight, dust, salts.

- The equipment should not be submitted to inclination, excessive vibrations, or blows (including 

during transportation and handling).

- The equipment must be installed in a level and stable place.

Before transporting the compressor, all air from the tank must be exhausted.

Summary of Contents for 40L

Page 1: ......

Page 2: ...ni industrial LTDA C N P J 59 064 766 0001 82 Avenida Professora Luiza Garcia Ribeiro 130 Santa Rosa de Viterbo SP Brasil For improved safety Read and understand all the instructions contained in the...

Page 3: ...arnings during the installation of the equipment 17 Recommendations for preserving the equipment 17 Precautions and warnings during the use of equipment 18 Precautions and warnings after the use of eq...

Page 4: ...pment is for dental use use only It must be operated and utilized by specialized professional certified professional according to the legislation of the country and following the instructions of the m...

Page 5: ...ate the equipment s operation and maintenance Safety System with valve that starts running for pressure release if there is any failure from the pressure switch and overload shield in order to protect...

Page 6: ...gine 05 On off switch 06 Inner pressure gauge manometer 07 Safety valve 08 Overload protector 09 Register of the outlet pressure 10 Manometer of the outlet pressure 11 Outflow rate register 12 Drainag...

Page 7: ...ral features Supply voltage and frequency 40 and 65 Liters 220V 10 60Hz or 127V 10 60Hz Supply voltage and frequency 150 Liters 220V 10 60Hz Rated current 40L 127V 13 A 40L 220V 6 7 A 65L 127V 13 A 65...

Page 8: ...cfm 65l 283 l min 10 cfm 150l 566 l min 20 cfm Max pressure 40l 120 psi 8 3 bar 65l 120 psi 8 3 bar 150l 120 psi 8 3 bar Number of Cylinders 40l 2 65l 2 150l 2x2 Other specifications Head weight 40L...

Page 9: ...9 Dimensions 40 LITERS TECHNICAL SPECIFICATIONS...

Page 10: ...10 Dimensions 65 LITERS TECHNICAL SPECIFICATIONS...

Page 11: ...11 Dimensions 150 LITERS TECHNICAL SPECIFICATIONS...

Page 12: ...ay from direct sun light exposure Packing to be transported and or stored with care should not suffer drop and neither receive impact Temperature limit for the packing to be stored or transported Turn...

Page 13: ...ute this task Alliage bears no responsibility for damages or accidents caused by poor installation executed by a technician not authorized by Alliage Only after the equipment has been installed and du...

Page 14: ...2 psi and so successively and automatically If the pressure switch fails the safety valve 07 will start running by releasing the excessive pressure Voltage Rated current Circuit breaker 127V 10 13 A 1...

Page 15: ...sal Open the register slowly until all the accumulated water is drained and air starts to flow again Close the register firmly so that no leakage can occur Compressed air outlet The air pressure on th...

Page 16: ...hPa to 1060 hPa 525 mmHg to 795 mmHg Operation altitude 2000m Attention The Equipment maintains its condition of safety and efficacy provided that it is maintained stored as mentioned in this instruct...

Page 17: ...apacity while using it does not exceed their technical specifications Alliage assumes no liability for damages accidents resulting from improper use or non compliance with the instructions described i...

Page 18: ...islation of the country Pay attention to the local legislation of the country for the conditions of installation and disposal of residue Precautions to be adopted against foreseeable or uncommon risks...

Page 19: ...eventive Maintenance The equipment should be calibrated routinely as per the legislation in force in the country But never with a period exceeding 3 years In order to protect your equipment seek Allia...

Page 20: ...rective Maintenance Alliage states that the supplying of the circuits diagram Part lists or any other information that permits the technical assistance by the user can be requested since previously ag...

Page 21: ...an the specified Connect the compressor to the correct network Wait for the regularization of network The compressor does not re aches the maximum pressure lesser efficiency works for a short period o...

Page 22: ...resentative We call your attention to our authorized resellers chain Only this chain will keep your equipment constantly new because it has trained technical assistant and specific tools for the corre...

Page 23: ...23...

Page 24: ......