Capacity of dental sets

40L: 1 dental set

65L: 2 dental sets

150L: 3 dental sets

Air Tank capacity

40L: 40 liters

65L: 65 liters

150L: 150 liters

Filling Time

40L: 1'53"

65L: 3'32"

150L: 3'52"

Theoretical displacement

40l: 283 l/min - 10 cfm

65l: 283 l/min - 10 cfm

150l: 566 l/min - 20 cfm

Max pressure

40l: 120 psi - 8,3 bar

65l: 120 psi - 8,3 bar

150l: 120 psi - 8,3 bar

Number of Cylinders

40l: 2

65l: 2

150l: 2x2

Other specifications

Head weight

40L: 15 Kg

65L: 15 Kg

150L: 2x15 Kg

Weight with packaging

40L: 48 Kg

65L: 54 Kg

150L: 107 Kg

Weight

With packaging (width x length x height)

40L: 528x528x800 mm

65L: 528x528x1060 mm

150L: 545x1200x935 mm

Dimensions

TECHNICAL SPECIFICATIONS

Summary of Contents for 40L

Page 1: ......

Page 2: ...ni industrial LTDA C N P J 59 064 766 0001 82 Avenida Professora Luiza Garcia Ribeiro 130 Santa Rosa de Viterbo SP Brasil For improved safety Read and understand all the instructions contained in the...

Page 3: ...arnings during the installation of the equipment 17 Recommendations for preserving the equipment 17 Precautions and warnings during the use of equipment 18 Precautions and warnings after the use of eq...

Page 4: ...pment is for dental use use only It must be operated and utilized by specialized professional certified professional according to the legislation of the country and following the instructions of the m...

Page 5: ...ate the equipment s operation and maintenance Safety System with valve that starts running for pressure release if there is any failure from the pressure switch and overload shield in order to protect...

Page 6: ...gine 05 On off switch 06 Inner pressure gauge manometer 07 Safety valve 08 Overload protector 09 Register of the outlet pressure 10 Manometer of the outlet pressure 11 Outflow rate register 12 Drainag...

Page 7: ...ral features Supply voltage and frequency 40 and 65 Liters 220V 10 60Hz or 127V 10 60Hz Supply voltage and frequency 150 Liters 220V 10 60Hz Rated current 40L 127V 13 A 40L 220V 6 7 A 65L 127V 13 A 65...

Page 8: ...cfm 65l 283 l min 10 cfm 150l 566 l min 20 cfm Max pressure 40l 120 psi 8 3 bar 65l 120 psi 8 3 bar 150l 120 psi 8 3 bar Number of Cylinders 40l 2 65l 2 150l 2x2 Other specifications Head weight 40L...

Page 9: ...9 Dimensions 40 LITERS TECHNICAL SPECIFICATIONS...

Page 10: ...10 Dimensions 65 LITERS TECHNICAL SPECIFICATIONS...

Page 11: ...11 Dimensions 150 LITERS TECHNICAL SPECIFICATIONS...

Page 12: ...ay from direct sun light exposure Packing to be transported and or stored with care should not suffer drop and neither receive impact Temperature limit for the packing to be stored or transported Turn...

Page 13: ...ute this task Alliage bears no responsibility for damages or accidents caused by poor installation executed by a technician not authorized by Alliage Only after the equipment has been installed and du...

Page 14: ...2 psi and so successively and automatically If the pressure switch fails the safety valve 07 will start running by releasing the excessive pressure Voltage Rated current Circuit breaker 127V 10 13 A 1...

Page 15: ...sal Open the register slowly until all the accumulated water is drained and air starts to flow again Close the register firmly so that no leakage can occur Compressed air outlet The air pressure on th...

Page 16: ...hPa to 1060 hPa 525 mmHg to 795 mmHg Operation altitude 2000m Attention The Equipment maintains its condition of safety and efficacy provided that it is maintained stored as mentioned in this instruct...

Page 17: ...apacity while using it does not exceed their technical specifications Alliage assumes no liability for damages accidents resulting from improper use or non compliance with the instructions described i...

Page 18: ...islation of the country Pay attention to the local legislation of the country for the conditions of installation and disposal of residue Precautions to be adopted against foreseeable or uncommon risks...

Page 19: ...eventive Maintenance The equipment should be calibrated routinely as per the legislation in force in the country But never with a period exceeding 3 years In order to protect your equipment seek Allia...

Page 20: ...rective Maintenance Alliage states that the supplying of the circuits diagram Part lists or any other information that permits the technical assistance by the user can be requested since previously ag...

Page 21: ...an the specified Connect the compressor to the correct network Wait for the regularization of network The compressor does not re aches the maximum pressure lesser efficiency works for a short period o...

Page 22: ...resentative We call your attention to our authorized resellers chain Only this chain will keep your equipment constantly new because it has trained technical assistant and specific tools for the corre...

Page 23: ...23...

Page 24: ......

Reviews: