22
FOR THE FITTER
INSTALLATION INSTRUCTIONS
Before installation, check whether the local distribution conditions, the type of gas and the pressure correspond with the factory
settings of the appliance.
COMBUSTION AIR
The premises must be equipped with air inlets or an air ventilation system admitting a minimum volume of combustion air equal to
the value given in the table below according to the type(s) of appliance(s) fitted in the premises.
Type of appliance
Airflow rate m3/h
SAEY 92 TR
SAEY 92 TR
21.6
CONNECTION TO THE CHIMNEY
The chimney must be thoroughly cleaned before making any attempt to connect the appliance to a chimney outlet to which another
appliance was connected previously. A discharge pipe with a diameter of 100 mm must be inserted in the outlet stub to connect the
appliance to the chimney.
The connection can be made secure by driving a pin with a diameter of 4 mm into the aperture in the outlet stub. Be careful not to
push the discharge pipe too far into the chimney.
Several appliances may be connected to one flue duct if that channel is specially equipped for the purpose, e.g., a Shunt chimney.
Flue gases leaving the appliance may not be allowed to travel in a downward direction.
Important:
If the chimney is coated with flammable material, all contact between that material and the gas fire and discharge pipe
must be avoided in order to prevent fire.
CONNECTION TO THE GAS PIPE
The connection must be stress-free and must be checked for gastightness by means of soapy water.
The gas supply pipe must be fitted with a gas tap which is located as near as possible to the appliance.
FITTING THE INCANDESCENT ELEMENTS (Fig. 3)
Egally spread the vermiculite ( G ) on the burner surface and if provided for at the left-hand and the right-hand sides of the burner.
All logs are marked with a letter at the bottom.
Position the logs on the burner as indicated in (fig.3).
The supplied glow flakes (C) can be spread at will on top of the vermiculite granules to obtain an optimal glowing effect. You do
not have to use the entire contents of the bag.
Never have the heater burn without vermiculite granules on the burner.