All local directives, including those relating to national and European standards, must be
observed when installing the stove.
Only an appliance connected by an installer guarantees the observance of the directives on building
construction and fire prevention. This is essential for the correct and safe operation of the stove. You
can find the authorized dealers on our website www.saeyheating.com.
The service life of your appliance depends on correct installation, proper operation and regular
maintenance.
Installation
The stove may only be installed on a floor capable of holding the correct weight (see technical details).
If this is not the case, necessary measures must be taken in order to increase the carrying capacity.
In order to level out the stove, it is equipped with adjustable legs ( adjusting screws ). Adjust these if
necessary so that the stove is levelled out as much as possible. Adjustments can be made with a wrench.
The chimney
Before connecting the stove to a chimney, please check the dimensions and quality so that they
correspond to local directives. If necessary the dimensions must be calculated.
The stove can be connected on the chimney in a direct way. The diameter of the exhaust pipe must
correspond with the outlet of the stove.
A proper functioning of the stove can be guaranteed with a chimney draft between 12 and 22 Pa. When
the chimney draft is too high, a draft valve must be built within.
Never reduce in diameter smaller than the diameter of the stove exit diameter.
Consider the next steps in case of insufficient chimney draft :
-
Make the chimney longer
-
Improve the isolation of the chimney. ( avoids cooling of the fumes )
-
Improve the supply of fresh air
-
Improve the density of the chimney
Installing the stove to the Chimney
With rear connection, the stove can be connected directly to the chimney. If you opt for a top
connection, the pipe nozzle must be fitted to the top plate and the exhaust cover to the rear panel.
It is important that these parts are sealed airtight. The diameter of the flue pipe must correspond to the
diameter 130 mm of the stove's pipe nozzle.