61
For an exact setting, use the respective setting
marks "D" below the numerical scale.
For example, to set an old chimney with an
effective chimney height of approx. 4 m,
the pointer of the adjustment disk should be
set to the first D-mark.
For example, to set an old chimney with an
effective chimney height of approx. 8 m,
set the pointer of the control disk at the
D mark below 8.
After adjustment, retighten the locknut of
the upper control disc of the VSR.
Combustion air supply
In order to have a perfect combustion, sufficient fresh air must be supplied. The required oxygen arrives
from the back and in best ways out of the premises.
HINT : Keep in mind that the presence of other stoves or venting installations in the same room(s) will
have disruptive effect on the functioning of your stove.
I
f there are still fumes coming back from the chimney due to bad weather conditions ( fog, storm, … )
and within 15 minutes after detonating you should stop trying to light up the fire, until better weather
conditions have arrived.
ATTENTION ! In no way whatsoever, fresh air may never be supplied from rooms where inflammable
or volatile materials are present.
The described settings assume a rear connection and a connector with a length of approx.
80 cm.
With a shorter connector, an effective height of more than 10 m can still be bridged. With
longer connector lengths, the higher heat emission of the flue gases upstream of the
chimney must be taken into account.