11
RELOADING
1. Open the air inlet fully (C)
2. Open the door carefully.
3. Use the poker to spread the glowing logs over the bottom.
4. Place new logs on the embers.
5. Close the door and allow the fire to resume.
6. Select a setting.
PLEASE NOTE!
It is recommendable to load no higher than the vermiculite walls, or to load no more wood
than the normal quantity given in table 2.
POSSIBLE SETTINGS
The stove has a higher output when the door is closed. In this way it produces heat in
completely safety by radiation and convection.
We can choose from 3 possible settings.
A.
Very high convection and radiation heat emission.
High wood consumption.
Open the primary air inlet completely to obtain a keen and fast flame. This setting should
be used only to light the fire. Once the stove is hot, select another position (see B or C).
B.
Very high convection and radiation heat, moderate wood consumption with minimum
pollution and maximum output. Gradually close the air regulator to maintain a good flame
without burning intensely. At this setting a fully loaded appliance should be able to burn
all night and still give off good convection heat. Using extremely dry wood and an
appropriate flue draught, the window will stay clean for longer.
C.
Average convection and radiation heat - low wood consumption. Close the air regulator
until the flame almost extinguishes. In this way the stove will burn all night (depending on
the flue draught) but the window will become dirty because combustion is not complete.
The choice of setting depends on the choice of capacity and the flue draught. The flue draught
can also be dependent on weather conditions.
To remind you, the more open the air regulator, the greater the radiation but with less heat
convection, and, more particularly, greater wood consumption. For maximum heat and output
choose setting "B".