8
XL-PH10409UM-en-US Rev C · 2012-08-03 · Amendments and errors reserved. © SAF-HOLLAND, Inc.
Mounting Instructions
6. Pintle Hook, Plunger,
and Air Chamber with
Bracket Installation
NOTE:
Holland recommends a Type 24
air chamber.
Before installing the pintle hook, plunger
and air chamber with bracket
(Figure 4)
,
make sure that the mounting structure is
of sufficient strength to support the rated
capacity of the pintle hook. Refer to SAE J847
for structural performance requirements.
1. Install the pintle hook with air chamber
and bracket to the mounting structure
using the bolt hole pattern as specified
(
Figure 6)
.
2. Verify mounting structure hole pattern
matches the dimensions listed
(Figure 6)
.
3. Insert the bottom four (4) bolts of
the pintle hook using four (4) new 3/4"
diameter Grade 8 bolts, ASTM Grade C
lock nuts, and hardened 3/4" washers
(Figure 5)
.
Figure 4
Figure 5
Figure 6
'063
(3"%&
#0-54
'063
(3"%&$
-0$,/654
'063 8"4)&34
2.38"
(60.3 mm)
7.50"
(190.5 mm)
4.75"
(120.7 mm)
Ø .81"
(20.6 mm)
THRU (6 REQ.)
6.62"
(168.2 mm)
5.00"
(127.0 mm)
2.50"
(63.5 mm)
7.88"
(200.0 mm)
5.19"
(131.8 mm)
Ø 3.25"
(82.6 mm)
3.31"
(84.1 mm)
2.13"
(54.0 mm)
2.00"
(50.8 mm)
2.38"
(60.3 mm)
.38"
(9.5 mm)
Ø .69"
(17.5 mm)
THRU (2 REQ.)
Ø 1.38"
(34.9 mm)
THRU
5.00"
(127.0 mm)
7.75"
(196.9 mm)