The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide
•
Rev. 1.3
•
© SAF Tehnika JSC 2010
28
2.4.1 RS-232 Serial Management Port
RS-232 serial management port provides terminal management via connected PC or
another terminal device or modem.
The terminal connected to serial management port provides the same management
functionality as Telnet interfaces (refer to
Chapter 2.3.2
). In order to interconnect the CFIP
Lumina and the management term
inal directly through serial ports, a “straight through”
modem cable is required.
Figure 2.18.
Serial connection to CFIP Lumina
To connect PC to RS232 management port using
Hyper Terminal
program (program is
included in any Windows version), proceed as described below.
1.
Connect the PC to the RS232 serial port by means of “straight through” or modem
serial cable (null-cable).
2.
Run “Hyper Terminal” program.
3. Make a
New connection
and enter connection name.
(!)
Syntactic notes for command prompt commands
–
Commands are in
bold
font.
–
All arguments (variables) are in
italic
font.
–
Subcommands and keywords are in regular font.
–
Arguments in square brackets ([ ]) are optional but required arguments are in angle
brackets (<>).
–
Alternative keywords are grouped in braces ( {} ) and separated by vertical bars
( | ).
–
The purpose of each command will be displayed if command is typed with
“?” at the
end (or any unrecognizable string) is entered, e.g.,
radio ?
The management system is automatically restarted if it freezes. This is performed by the
watchdog timer. Restarting of the management system does not affect (interrupt) the Ethernet
traffic.