The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide
•
Rev. 1.3
•
© SAF Tehnika JSC 2010
33
3
Status Window
The main window in Web GUI is status window, which shows all main system
parameters, and, in case of failure or any other problem, it tints a specific parameter in red.
To have better understanding on status window, we will go through every field of the
status window.
Figure 3.1.
1. Shows the name of this CFIP Lumina, its IP address, serial number and
uptime since the last restart. If uptime is displayed in red, the connection to
CFIP management port was lost;
2. Shows the firmware version this CFIP Lumina is currently using;
3. Logout button allows ending the current Web GUI management session and
logging in as a different user if necessary. After pressing the button, you are
automatically redirected to the login page;
4. The tree of Web GUI sections;
5. Shows short summary of the main operational parameters of local and
remote system.
Rx level (or RSL) at both ends must not differ significantly from the
previously calculated value.
Modulation indicates which modulation mode is used. For better
operation the same modulation must be set at both ends.
Radial MSE is explained below in the
Chapter 3.1
.