The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide
•
Rev. 1.3
•
© SAF Tehnika JSC 2010
44
2.
admin
– Enter new password (length: 4..30 characters) –
allows entering
preferable „admin‟ account password. Maximal length of the user name
cannot exceed 30 symbols. By default password for „admin‟ account is
„
changeme
‟. Admin account has full control of the CFIP configuration
process.
3.
Hide password(-s)
–
Hides typed in password. This option unchecked will
display typed in password in plaintext.
4.
Pressing “Execute configuration” applies changes made to the corresponding
section only for the local side CFIP Lumina
. If “Rollback on” is selected,
configuration will be reverted in case of erroneous configuration changes
applied.
More detailed status controls are available in command prompt, which include:
4.2.2 Names Configuration
Additional user management commands in Telnet/serial interface
Command
Description
access login
<name> <password>
Logs on as a user specified by <name> and <password>.
access logout
Logs current user out.
access set
<guest|admin>
<password> [plaintext]
Allows specifying a new password for a specific account (admin or
guest). „
plaintext
‟ option will save the password in plaintext in
configuration script without encrypting it (by default saved
passwords in configuration file are encrypted).
access show
Shows user name and password of a user currently logged
on.
access list
Shows the list of usernames and passwords the current account is
able to manage (if logged on as admin, „guest‟ and „admin‟ account
passwords will be seen).