The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide
•
Rev. 1.3
•
© SAF Tehnika JSC 2010
70
Figure 5.6.
Functional architecture for data collection, history and thresholding treatment
5.2.2 Performance Values
Threshold Seconds (TS)
The TS is defined as one second period during which the detected value is outside of
predefined thresholds. The current value of the counter associated with TS should be
readable by the managing system on request. In case a threshold associated to TS counter is
changed, the current value of the counter should be reset to zero.
Tide Mark (TM)
The TM is a mechanism that records the maximum and the minimum value reached
during measurement period. The tide mark values are automatically reset to the current value
assumed at the beginning of each measurement period. The TM is therefore composed of
two values: the minimum and the maximum value. Comparison between the current value
and the minimum and maximum values is performed on a second basis.
5.2.3 Performance Management in Web GUI
The main performance management tool in the CFIP Lumina is Web interface, allowing
user to review performance measurements in a very convenient and visualized way.
Going to „Performance
Performance log‟ in navigation panel on the left side of the Web
GUI window will lead you to the log parameters‟ selection screen, where you will be able to
choose between 6 different parameters to display in summarizing performance log or pick
„ALL‟ to display all 6 parameters in conjoint log which is shown in
Figure 5.7.