6 Miscellaneous Controls in Web Graphic User Interface
These controls are located in the Navigation Panel under the
“Tools” item.
6.1 Configuration File
This section allows working with CFIP configuration script.
The management module has RAM and EEPROM chips onboard. When CFIP is booted
up, bootstrap is loaded from the EEPROM into RAM. The bootstrap contains the parameters
that were previously stored in EEPROM using
write
and/or
cfg write
commands. These
parameters are stored in EEPROM in the form of script and during boot up, the script
parameters are loaded into RAM. These parameters can be freely changed in run-time, -
changing the data in RAM. If the CFIP is shut down without saving the current configuration
(script) in EEPROM, the original configuration will be restored from EEPROM during next
boot-up time.
Example of script can be observed on the screenshot below.
The script can be edited:
–
string can be added by simply entering required string (see Nr. 7 on the screenshot
below) or by executing command in CLI or in the appropriate Web GUI section (the script
will be supplemented with the new string or the instant string entry will be updated);
–
string can be deleted by entering appropriate line number (see Nr. 2 on the screenshot
below) or by using
“
cfg delete
<string#>” in CLI.
The changes can be saved in EEPROM by pressing “Cfg write” button (see Nr. 3 on the
screenshot below) or by entering “
cfg write
” command in CLI.
Explanation of customization fields:
1. Window shows contents of configuration script. Commands contained in this
configuration script are executed at every system start-up (command line
–
cfg show
);
(!)
Note! The parameters that are not specified in the configuration script will have their
default values when the CFIP is restarted.