SG COMPACT
ADDING FILTERS
8
3
ADDING FILTERS
3.1
Overview
In order to use SG Compact in the field it is necessary to use external filters. Filters
ensure filtration of additional harmonics which occur in the device’s mixer.
The tables below summarize filters’ usage with appropriate SG Compact units.
Frequency band, GHz
SG unit*
Filter
6 7 8 10 11 13 15 17 18 23 24 26 28 32 38 42
J0SSAG11 J0ALPF09
J0SSAG12 J0ALPF14
J0SSAG13 J0S22WAF01
J0SSAG14 J0S38WAF01
*See Chapter 1.2. Technical specification further details.
Legend:
Corresponding filter should be used at this frequency band.
Filter usage is not required as harmonics for particular SG Compact comply with
levels defined by radio standard.
The SG Compact unit does not support these frequencies.
Filters:
P/N
Description
J0ALPF09
Low pass filter with cut-off frequency 9 GHz
J0ALPF14
Low pass filter with cut-off frequency 14 GHz
J0S22WAF01 Low pass filter/waveguide-to-coax converter with cut-off frequency 21 GHz
J0S38WAF01 Low pass filter/waveguide-to-coax converter with cut-off frequency 33 GHz
Low pass filter with cut-off frequency 9 GHz
P/N J0ALPF09
Low pass filter with cut-off frequency 14 GHz
P/N J0ALPF14
OR
OR