15. CYLINDER
16. MAGNET SENSOR
Electrical data
Behind the text Safetron on
face plate is the magnet
sensor.
Place magnet infront of the
text Safetron on face plate.
Adjust for best function.
Magnet sensor
Power supply.
Relay.
Power consumption (mA) at 12 VDC
Standby 20
Motor active 200
Blocked 400
Power consumption (mA) at 24 VDC
Standby 15
Motor active 100
Blocked 200
10-30 VDC / 8-24 VAC
no polarity requirements
60V / 0,2A
Unlocking / locking time. Under 0,3 sec
EN
ml 151
ML 151
ML 152
ML 128
ML 135
Modell ML 151, ML 152
Mounting the cylinder on lock case. Arrow shall point
upp on both sides.
Modell ML 128, ML 135
Mounting the cylinder on lock case. Arrow shall point at
face plate on both sides.
Art. nr.
Accessories
Cable 6m:
Cable 10m:
Strike plate
with magnet 101
for ML 151, 152:
Strike plate
with magnet 102
for ML 128, 135:
202144629
202144628
202144345
500557