CABLE RECOMMENDATIONS
Cable types like data / telecom / signal (single core) with areas between 0.1-0.2 mm may not be used to
supply power to the lock. Warranty is void if installation instructions are not followed.
Recommended minimum cable area between the power supply–control unit-lock cases (total length)
N.B.
It is essential that the power supply to the control unit has a correct dimensioned cable, this to avoid a voltage drop
that interferes with the function of the lock.
At common supply of several locks / access control / reader / centers and the like, the total
power consumption is taken into account when calculating the cable area.
Cable length
12-24 VDC
0-10m
0,17mm²
11-20m
0,34mm²
21-40m
0,68mm²
61-80m
1,36mm²
81-100m
1,7mm²
RECOMMENDATIONS WHEN INSTALLING MOTOR LOCKS
Recommendations when installing motor locks
• Read and follow the installation instructions.
• In cases where double cylinder is not used, a magnetic thumb turn should be used. This is to ensure
that the position of the cylinder will not block the deadbolt.
• Motor locks should to the greatest extent be used electrically for best performance.
Manual locking/unlocking with a key should therefore be minimized.
• Maintenance e.g. adjustment and lubrication
should only be performed by a trained professional.