NXP Semiconductors
UM11637
FRDMGD3160DCMHB evaluation board
4.4.3 Power supply and jumper configuration
Figure 5. Power supply and jumper configuration
Jumper
Position
Function
1-2 (default)
dead time fault protection enabled (high side)
PWMHSEL (J11)
2-3
dead time fault protection disabled (use for short-circuit testing)
1-2 (default)
dead time fault protection enabled (low side)
PWMLSEL (J10)
2-3
dead time fault protection disabled (use for short-circuit testing)
open (default)
VCCREG controls gate voltage
JVCCH (J2) and
JVCCL (J8)
closed
VCC and VCCREG are tied together
1-2 (default)
chip select for normal operation
CSB (J23)
2-3
chip select for daisy chain operation
closed (default)
normal operation
MOSI (J22)
open
daisy chain operation
1-2 (default)
normal operation
MISO (J24)
2-3
daisy chain operation
closed (default)
normal operation
MISO (J21)
open
daisy chain operation, except for last board in chain
Table 4. Jumper definitions
UM11637
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2022. All rights reserved.
User guide
Rev. 2 — 3 February 2022
11 / 42