7.3 Battery charging
The lift’s batteries are located under the chassis control panel. The
batteries are of AGM type, they are leak-proof and cannot be refilled
with battery fluid. When batteries need to be replaced, this should
only be done with batteries approved by the manufacturer.
The status of the battery charge can be seen on a lamp located next
to the chassis pillar (10). The plug (14) must be connected to 230V
to be able to read the status. The lift’s built-in charger optimally
charges the batteries, so that overcharging cannot take place.
Battery acid is very corrosive. Always wear safety goggles
when working with and near the batteries. Immediately rinse
any spilled acid with clean water. Consult a physician in case of
contact with battery acid.
WARNING!
Charge the batteries in a ventilated area. Do not charge the
batteries near open fire or where there is a risk of sparks being
generated.
Red light
- Charging in progress
Green light
- Charging complete
NOTE!
The charger must be connected to a socket with earth-fault
protection. Do not use the lift while charging.
NOTE!
The switch on the chassis control panel must be in position "1"
for charging to take place. When charging is not required, the
switch should be in position "0".