background image

14

© 2010 SafeLine and all the SafeLine products and accessories are copyrighted by law.

Programming

ENGLISH V. 4.02

PROGRAMMING DATA

CODE

DATA

COMMENTS

Enter programming mode

00

Enter password

* - - - - #

Default = 0000

Exit programming mode

*00*#

ALARM CODES 

CODE

DATA

COMMENTS

P100 ID code

*01*

- - - - - - - - #

P100 is always 8 digits 

CPC ID code

*02*

- - - - - - #

CPC 6-8 digits

Q23 ID code

*03*

- - - - - - - - - - - - #

Q23 is always 12 digits

TELEPHONE NUMBERS

CODE

DATA

COMMENTS

1st Phone number

*11*

- - - - - - - - - #

Phone number to alarm receiver 0-16 digits.

If calling through a switch board

, delay time can be set by 

adding asterisks between leading number and telephone number. 
Each asterisk is equal to one second delay.

Example:

 *11*(0)**1234567#

2nd Phone number

*12*

- - - - - - - - - #

3rd Phone number

*13*

- - - - - - - - - #

4th Phone number

*14*

- - - - - - - - - #

CALL TYPE

CODE

DATA

COMMENTS

Call type 1st number

*21*

- #

Change call type 1-4:th number:   
0 = P100
1 = VOICE (Default)
2 = Q23
3 = CPC

Change this only if your alarm operator is using any of the 
mentioned protocols. 

Call type 2nd number

*22*

- #

Call type 3rd number

*23*

- #

Call type 4th number

*24*

- #

Call type LMS number

*30*

- #

LMS(Lift Monitoring System) call type
0 = P100 
3 = CPC (Only battery alarm)

TEST ALARM/BATTERY ALARM

CODE

DATA

COMMENTS

LMS phone number

*16*

- - - - - - - - - #

LMS(Lift  Monitoring  System)  phone  number  to  alarm  receiver  / 
SLCC

Test alarm

*17*

- - - - - - - - - #

Phone number to test alarm receiver / SLCC

Days between tests

*27*

- - #

Number  of  days  between  test  alarms,  00-99  days.  Always  two 
digits. Max 3 days according to EN 81-28.
00 = No test alarms

Test alarm protocol

*31*

- #

Protocol test alarm 
0 = P100
3 = CPC
4 = Phone number used as ID.

ALARM CHARACTER

CODE

DATA

COMMENTS

Alarm character 1st number

*41*

- - #

Alarm character. only when using CPC as alarm protocol normally 
10 or 27 check with your alarm company !

Alarm character 2nd number

*42*

- - #

Alarm character 3rd number

*43*

- - #

Alarm character 4th number

*44*

- - #

Alarm character LMS

*45*

- - #

LMS(Lift Monitoring System) (Battery alarm) Normally 17

Alarm character Test alarm 

*46*

- - #

Normally 26

Summary of Contents for MX2

Page 1: ...SafeLine MX2 Installation manual ENGLISH V 4 02 10 2010 Small inexpensive and intelligent Probably the world s smallest EN81 28 compatible lift telephone...

Page 2: ...TECHNICAL DATA Power Supply voltage 10 30 VDC Current consumption max 50 mA Emergency signal button Can be set as NO or NC 10 30VDC Auxillary input Can be set as NO or NC 10 30VDC Size HxWxD 130x78x1...

Page 3: ...onal safety 4 Component list 5 Measurements 6 Wiring diagram 7 Wiring diagram SafeLine MX2 on PSTN line 8 LED indication 9 Programming interfaces 10 Programming method 11 Programming unit numbers 12 P...

Page 4: ...stallation or illegal changes repairs or additions Claims under warranty are likewise excluded in such cases The technical data is the latest available The manufacturer accepts no liability arising fr...

Page 5: ...1 2 5 Installation ENGLISH V 4 02 COMPONENT LIST 1 RJ45 connector For power emergency button phone line and auxillary input 2 RS232 PC connection For firmware update and programming with SafeLine Pro...

Page 6: ...02 Flush mount SafeLine MX2 with pictograms Article number SLMX_Rec Pic Flush mount SafeLine MX2 with pictograms and emergency alarm button Article number SLMX_Rec PicB Surface mount SafeLine MX2 wit...

Page 7: ...d cable Colours when using flat cable Voltage supply 0V Voltage supply 0V Voltage supply 10 30V Voltage supply 10 30V Additional input filter Additional input filter Alarm button Alarm button Telephon...

Page 8: ...are copyrighted by law Installation ENGLISH V 4 02 Daisy chain wiring serial wiring Parallel wiring WIRING DIAGRAM SAFELINE MX2 ON A PSTN LINE MAX 9 UNITS Phone line in Phone line in Unit numbers can...

Page 9: ...System LED Flashing once every 5 seconds Telephone line OK Flashing two times every 5 seconds No telephone connection available Flashing twice every second Calling out Light steady Call connected Flas...

Page 10: ...nstallation or at site after installation with a programming cable PCable Remote programming For remote programming you can use any PSTN tone dial phone Dial the phone number of the SafeLine Enter the...

Page 11: ...e programming Start programming One long beep only last code has to be reentered Programming mode Enter code and setting Refer to parameter list Press 00 Call has ended 2 short beeps 2 short beeps No...

Page 12: ...umber 1 Program unit as number 2 9 End Programming Press the next unit number repeatedly until hearing 3 beeps Enter the password Terminate programming First unit answers The next unit answers Unit pr...

Page 13: ...e number to emergency call centre to 45645687 Set phone number 42345687 for test alarm Send test alarm every third day Set test alarm protocol to P100 Set alarm button delay to 10 seconds PROGRAMMING...

Page 14: ...CPC Change this only if your alarm operator is using any of the mentioned protocols Call type 2nd number 22 Call type 3rd number 23 Call type 4th number 24 Call type LMS number 30 LMS Lift Monitoring...

Page 15: ...DATA COMMENTS Emergency signal in speaker 71 The speaker siren will sound at emergency call 1 On Default 0 Off Ring tone timeout 72 Number of ring signals before dialling the next number Additional in...

Page 16: ...Alarm button delay time 87 Delay time from pressing the alarm button until activating the alarm 00 25 seconds Default 05 Alarm button type 89 0 Normally open contact NO Default 1 Normally closed conta...

Page 17: ...5 times Short tone in the speaker Green LED flashes every 5 sec if valid telephone line connected and set to standard Yellow LED flashes every 5 sec No connection Yellow LED flashes 5 times Long tone...

Page 18: ...on Calling 1st phone number Wait 1 minute Calling 2nd phone number Calling 4th phone number Calling 3rd phone number Line missing or busy Emergency alarm activated Receiving tone No No No No No Yes Ye...

Page 19: ...ar check the microphone Poor distorted sound quality Volume might be set too loud Lower the volume and check again Interfering noise when the call is connected The problem might be due to induction in...

Page 20: ...safeline eu SAFELINE EUROPE Blvd de la Woluwelaan 42 1200 Brussel BELGIUM Phone 32 0 2 762 98 10 Fax 32 0 2 762 97 10 E mail info safeline eu Support www safeline eu support...