background image

7

+

-

MIC

SL6

+ 12 V

+ 12 V

0 V

0 V

+ 12 V

+ 12 V

A

B

C

D

E

1

2

3

4

1

2

1

2

3

4

5

6

1

2

3

4

5

6

1

2

7

8

230 VAC

0 V

0 V

SL3000 v.5.01 EN

Grey

Grey

Orange

Orange

Black 

Black 

Red 

Red 

Blue

Blue

Green

Green

+ 12 V AT Alarm

+ 12 V AT Alarm

+ 12 V AT Alarm

+ 12 V AT Alarm

Yellow

Yellow

Brown

Brown

Yellow/Green

Yellow/Green

Wiring diagram 

- Cable type 1

Unconnected cables must be 

isolated, to avoid short circuiting.

Em. button 

NO / NC

Acoustic

signal

Summary of Contents for SL3000

Page 1: ...www safeline group com 11 2019 2019SafeLineandalltheSafeLineproductsand accessoriesarecopyrightedbylaw SL3000 Manual Lift emergency telephone CompliestoEN81 28andEN81 70standards SL3000 v 5 01EN...

Page 2: ...Activating the SIM card 12 Mounting 13 Programming interfaces 14 Programming method 15 Programming Unit numbers 16 Configuration examples SafeLine Autodialer Units 17 Parameter list 18 Operation 23 Fr...

Page 3: ...mA Emergency light Emergency light output 12V max 0 5A Acoustic emergency signal output 12 VDC max 0 5A Inputs 10 30 Volts 5 mA Optically isolated Relay outputs Max 2A 30V DC 0 5A 125V AC potential fr...

Page 4: ...acturer accepts noliability arisingfromprintingerrors mistakesorchanges Declaration of conformity Download The declaration ofconformity atourwebsite www safeline group com SafetyPrecautions Only train...

Page 5: ...GSM Net Call in out progress 4 RS232 PC connection For firmware update and programming 5 Slot for optional extra voice station card Two supplementary microphone speaker units can be connected for the...

Page 6: ...for PSTN line Connect telephone line here 3 GSM antenna connection SMA 4 SIM card holder 5 Volume controls For the extra remotes Turn right to increase the volume 6 Terminals For the extra voice stat...

Page 7: ...3000v 5 01EN Grey Grey Orange Orange Black Black Red Red Blue Blue Green Green 12 V AT Alarm 12 V AT Alarm 12 V AT Alarm 12 V AT Alarm Yellow Yellow Brown Brown Yellow Green Yellow Green Wiring diagra...

Page 8: ...0v 5 01EN Grey Grey Orange Orange Black Black Red Red Grey Grey Orange Orange Black Black For more information see parameter list code 88 Wiring diagram Cable type 1 Extra remote board Extra input 2 E...

Page 9: ...range White Orange White Orange Orange Green White Green White Blue Blue 12 V at alarm 12 V at alarm 12 V at alarm 12 V at alarm Em button NO NC Acoustic signal Brown Brown Brown White Brown White Gre...

Page 10: ...tra remote board Orange Orange Blue Blue Orange Orange Orange White Orange White Green White Green White Blue Blue Orange White Orange White Extra input 2 Extra input 1 Emergency light Green Blue Gree...

Page 11: ...ne out to next safeline Phone line in Phone line with RJ12 Connecting the phone line Parallel wiring Telephone line in Daisy chain wiring Serial wiring Telephone line in Wiring diagram SafeLine 3000 o...

Page 12: ...code 0000 or 1234 this to clear the old code in memory PIN code set to 0000 1234 or deactivate 1 Insert the SIM card in an ordinary cellular phone In the Security settings menu change the PIN code to...

Page 13: ...0v 5 01EN Mounting PSTN board GSM board Adding an extra station board Mounting Unplug the main power and battery before performing any changes To avoid GSM interference Place the main unit the station...

Page 14: ...fter installation with a programming cable from us Remote programming For remote programming you can use any PSTN tone dial phone Dial the phone number of the SafeLine 3000 Enter the function codes on...

Page 15: ...l restart with the new settings 2 short beeps 2 short beeps One long beep Invalid input Last code has to be reentered On site programming with handset Start programming 00 Enterthepassword 0000 Valid...

Page 16: ...The next unit answers Unit programming is done Programming the unit number Start programming 00 Enter the password 0000 Terminate programming 00 Unit number 82 n Programming Unit numbers To remotely...

Page 17: ...feLine Call Centre 1 Start configuration 2 1st phone number 3 2nd phone number 4 Call type 1st number 5 Call type 2st number 6 Alarm button delay 7 End configuration If at any time you need to start o...

Page 18: ...4th Phone number 14 CALL TYPE CODE DATA COMMENTS Call type 1st number 21 Change call type 1 4 th number 0 P100 1 VOICE Default 2 Q23 3 CPC Change this only if your alarm operator is using any of the m...

Page 19: ...Lift Car to alarm central 52 Speak This message will be played to the alarm receiver and in the car when the call is answered Make sure that there is no noise in the background when recording the mes...

Page 20: ...oming call Can be set from 00 16 00 Never answering Default 02 Unit number 82 Program Unit number 0 9 when units share phone line Detect dial tone 83 0 Off 1 On Default Set to off if SafeLine has prob...

Page 21: ...when the call is acknowledged green pictogram Relay 2 will be deactivated when the call is disconnected 2 DTMF controlled The relays can be activated remotely for 5 seconds Relay 1 will be activated...

Page 22: ...lift telephone When there is a voice response some ascending tones will be heard The call is validated by pressing 4 The call is terminated by pressing 0 The call is terminated without reciept notifi...

Page 23: ...s Rapidly flashing Yellow Activealarmnotreset Callingoutin progress LED 3 indicates thephoneline sstatus Continuousred NoSIM cardorcommunicationfailure whenusingGSM Flashing red Notelephonelineconnect...

Page 24: ...LED GreenLED Lightoff Noalarm activated TelephonelinenotOK Flashing slowly Flashing once every5 seconds Telephone line notOK Flashing once every5seconds UnitisOK Flashing quickly Flashing twiceeverys...

Page 25: ...ashes green if valid telephone line connected Connect a telephone to the RJ12 connector on the front of the SafeLine 3000 Internal dial tone Lift the handset Phone line dial tone Dial out All LEDs are...

Page 26: ...w 2 Make calls with a normal fixedphonelineandthroughGSM 3 Emergency calls tonumbersatthepress ofthealarmbutton 4 Test alarms at preset intervals 5 Sendreceipts toSLCC alarmreceiver for defined condit...

Page 27: ...7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 SL3000v 5 01EN Intercom between machine room car pit Top of car Press 1 to call the lift car...

Page 28: ...Emergency alarm activated Dial tone Calling 1st phone number Answer Calling 2nd phone number Answer Calling 3rd phone number Answer Calling 4th phone number Answer Alarm operator made connection Wait...

Page 29: ...can be reset by pressing the reset button Battery test If the reset button is pressed 3 times within 2 seconds a battery test will be performed The battery test takes about 20 minutes To cancel the ba...

Page 30: ...loud Lower the volume and check again Interfering noise when the call is connected If the main unit is installed on the car roof the problem might be due to induction in the phone cable According to...

Page 31: ...Technical requirements EN 81 28 2003 Lift Remote alarm on passenger and goods passenger lifts EN 12015 2014 EMC Emission Electromagnetic compatibility EN 12016 2013 EMC Lifts Immunity Electromagnetic...

Page 32: ...ost safeline no SafeLine Denmark Erhvervsvej 19 2600 Glostrup Denmark Tel 45 44 91 32 72 info dk safeline se SafeLine Headquarters Antennv gen 10 135 48 Tyres Sweden Tel 46 0 8 447 79 32 info safeline...