37
SL6+ v.3.30 EN
Operating
Fallback LMS codes:
Z001:
PSTN: If mains power is out longer than set time (Fallback Alarm
Delay), an LMS is sent with the code Z001.
Z002:
When power returns and has been back for more than set time,
an LMS is sent with the code Z002.
Z003:
GSM: If RSSI levels are lower than limit value (5) for set time (Fall-
back Alarm Delay), an LMS is sent with the code Z003
Z004:
When RSSI levels are higher than limit value (5) and has been for
more than set time, an LMS is sent with the code Z004.
Z005:
PSTN: If alarm drop-off fails through any of the interfaces (e.g.
no response, busy line, no P100 start tone/acknowledgement) and
Fallback is active, an LMS is sent with the code Z005.
Z006:
PSTN: If alarm drop-off fails through the prioritized interface,
the unit also tries the secondary interface. If drop-off fails through
any of the interfaces (e.g. no response, busy line, no P100 start tone/
acknowledgement) and Fallback is active, an LMS is sent with the code
Z006.
Z007:
GSM: If alarm drop-off fails through any of the interfaces (e.g.
no response, busy line, no P100 start tone/acknowledgement) and
Fallback is active, an LMS is sent with the code Z007.
Z008:
GSM: If alarm drop-off fails through any of the interfaces (e.g.
no response, busy line, no P100 start tone/acknowledgement) and
Fallback is active, an LMS is sent with the code Z007.
Z009:
If no dial tone is detected through outgoing PSTN call attempt,
call attempts are cancelled through PSTN so the unit may try GSM
immediately instead. If the call attempt is cancelled due to missing dial
tone while Fallback is active, an LMS is sent with the code Z009.
Fallback LMS
codes