Page 29
When a satisfactory setting has been achieved. Press
ENTER once.
The Reject Time should now be adjusted.
14) Press the ’Etc’ soft key the display now reads Signal
Shift 4## Reject Time ####sec
Etc
Place the sample pack with metal contaminant in the
front or rear edge on the conveyor belt and allow it to
pass through the detector without skewing or slippage.
Press the ’Reject Shift’ soft key and adjust the reject time
until the metal contaminated pack is cleanly rejected.
When accurate reject action has been achieved
Press ENTER once.
Using the ETC key will toddle the display between the
two pages to allow for any trimming to be done before
finally entering the data into memory.
When satisfactory settings have been achieved
Press ENTER once again.
The display will show the type of timer Set/ Updated for a
period of five seconds after which it returns to the main
menu.
15) Further check the operation and settings of the reject
mechanism by passing contaminated packs through the
detector.
Check packs with small metal samples placed in turn at
the front and rear of the pack then repeat the tests using
larger metal samples.
Note: Under normal running conditions with packs
continuously passing along the conveyor if the gap
between a metal contaminated pack and the adjacent
pack is less than half the pack length both packs may be
rejected.
If for any reason the settings of the timer are thought to
be incorrect repeat the whole of the setting up procedure
from step 1.