Available users and default codes
User
ID
Default Code
Master
N/A
12345678
Manager
01
123456
Users
02-49
Deleted, 6 digits
(Can be added by the Manager)
Time Delay
Override Users
50-59 Deleted, 6 digits
(Can be added by the Manager)
Warning: Default codes must be changed
immediately. The Master has overall administrative
control of the lock system and can therefore create
other users who can open the lock.
User hierarchy
Master > Manager (01) > Users 02-49 + 50-59
Master
The Master has administrative control of the lock
including Manager management but cannot open.
Manager (01)
The Manager and can open the lock, change their
own code, manager users, block the lock, audit and
manage time delay.
Users (02-49 + 50-59)
Users can open the lock and change their own
code. Users 50-59 also have the ability to override
time delay if in use and open the lock immediately.
Using the keypad
Older keypads may have a
key instead of an
key. Both keys function in the same way.
•
Press any key to wake the display
If a key is not pressed for 30 seconds, the display will automatically
switch off.
•
To scroll menu items press
•
To accept press
•
To exit a menu, press
to scroll to
EXIT
and
press
to accept.
•
To return to the main code-entry display, press
and hold
•
If a mistake is made during entry press
or allow
the display to timeout.
Access the Master menu
•
Press and hold
The display shows MASTER MENU
•
Enter the Master code
The display shows
TIME AND DATE SETTINGS
•
Once procedures are completed, press and hold
to exit the Master menu
Master menu structure
TIME AND DATE SETTINGS
>View and amend time and date
AUTOMATIC DST
>Scroll to ON or OFF
TIME LOCK SETTING
>WEEKLY TIME LOCK SETTING
>ADD NEW VALUES
>VERIFY OR DELETE VALUES
>EXIT
>CLOSING PERIODS SETTING
>ADD NEW VALUES
>VERIFY OR DELETE VALUES
>EXIT
>OPENING PERIODS SETTING
>ADD NEW VALUES
>VERIFY OR DELETE VALUES
>EXIT
>EXIT
SYSTEM AUDIT
>PC LINK
>SCROLL EVENTS
CHANGE MASTER CODE
>Enter the new code twice
MANAGER MANAGEMENT
>INSTALL / DELETE / DISABLE / ENABLE
DYNAMIC CODES
>Scroll to DISABLE or ENABLE
LOCK RECLOSURE MODE
(Motorbolt locks only)
>Select MANUAL or AUTOMATIC
PC LINK
>Initiate communication with a PC
EXIT
Set time and date
•
Access the Master menu
•
Press
to scroll to
TIME AND DATE
SETTINGS
•
Press
The display shows the current time and date
•
Press
again to enter values in the format
shown, using the 24-hour clock.
•
When the display shows
✓
after the date, press
The display loads the day, entry is complete
Automatic DST
The lock’s bolt must be in the open position to change
DST status.
•
Access the Master menu
•
Press
to scroll to
AUTOMATIC DST
•
Press
then
to select ON or OFF press ok
The display shows the current time and date
•
Press
The display shows CHECK/TIME DATE VALUES
as a reminder