Loudness:
> 85dB at 1 meter
Power consumption:
<4W
Height:
117.4 mm
Width:
77.4 mm
Depth:
36.3 mm
Working temperature:
-10 ° C + 40 ° C
Humidity:
0-95% RH
Warranty:
3 years
Service life:
5 years
Status
Description
Green
POWER LED
Yellow
FAULT LED
Red
ALARM LED
Sounder
Self test
Power on
FLASH
FLASH
FLASH
1 BEEP
Warming up
Approx. 180 sec. since
commissioning
BLINK
0.5s / 1s
DOES NOT LIGHT
DOES NOT
LIGHT
OFF
Watch
Normal work
FLASH
PERMANENTLY
DOES NOT LIGHT
DOES NOT
LIGHT
OFF
Test
Device test after pressing
the TEST / HUSH button
FLASH
PERMANENTLY
DOES NOT LIGHT
BLINK
0.5s / 1s
ALARM SOUNDS
ALARM
The device has detected
gas
FLASH
PERMANENTLY
DOES NOT LIGHT
BLINK
0.5s / 1s
ALARM SOUNDS
Mute
Press the TEST / HUSH
button during the alarm
FLASH
PERMANENTLY
DOES NOT LIGHT
BLINK
0.5s / 1s
OFF
Sensor failure
Contact service
FLASH
PERMANENTLY
SHINES
PERMANENTLY
DOES NOT
LIGHT
1 BEEP
Every 30 seconds
End of Life
Replace the device with a
new one
FLASH
PERMANENTLY
SHINES
PERMANENTLY
DOES NOT
LIGHT
3 BEEP EVERY 30
sec
Lack
Power
The power cord is
disconnected
DOES NOT LIGHT DOES NOT LIGHT
DOES NOT
LIGHT
OFF
DE
PL
CZ
SK
HU
RO
BU
UA
EN
Summary of Contents for SHG-01
Page 45: ...SHG 01 GS869 SafeMi SHG 01 SHG 01 DE PL CZ SK HU RO BU UA EN...
Page 46: ...SHG 01 SafeMi SHG 01 10 C 40 C SafeMi SHG 01 1 2 5 0 3 4 5 POWER 3 DE PL CZ SK HU RO BU UA EN...
Page 47: ...TEST HUSH DE PL CZ SK HU RO BU UA EN...
Page 48: ...5 SafeMi SHG 01 TEST HUSH AC 220 240V 50 60Hz DE PL CZ SK HU RO BU UA EN...
Page 51: ...SHG 01 GS869 SafeMi SHG 01 SHG 01 SHG 01 DE PL CZ SK HU RO BU UA EN...
Page 52: ...SafeMi SHG 01 10 C 40 C SafeMi SHG 01 1 2 5 0 3 4 5 POWER 3 DE PL CZ SK HU RO BO UA EN...
Page 53: ...TEST HUSH DE PL CZ SK HU RO BO UA EN...
Page 54: ...5 SafeMi SHG 01 TEST HUSH 220 240 50 60 DE PL CZ SK HU RO BO UA EN...
Page 57: ...SHG 01 SAFEMI HOME 2021...