7. SPECIFICATIONS

Central Unit
Power supply 230 V 

∼ 

1 N, 47–60 Hz 

Output voltage of the 
power source 5 V 1 A

Power con-
sumption

1 W

Wireless con-
nection

SAFERA RobustLink 2,4 
GHz. Range 10 – 100 m, 
depending on the build-
ing structure

Pollution 
degree

2

Power Control Unit
Compatibility Most electric cookers 

and hobs used in private 
homes.See specific 
compatibility on the label 
of the power control 
unit 

Ⓒ.

Power supply See the label of the 

power control unit 

Ⓒ.

Power con-
sumption

2 W
(PCU6.3 = 4 W)

Control type

According to IEC/EN 
60730 - 1 : Type 1.B

Pollution 
degree

2

Impulse volt-
age rating

4 kV

Operational 
ambient tem-
perature

See the label of the power 
control unit 

Ⓒ.

Ball pressure 
test rating

100 °C

PTI of insula-
tion materials

175...400

Designed 
number of 
automatic 
actuations

6000

IP class

See power control unit

Extinguisher Unit
Compatibility

Typical cooktop fires, 
including grease fires

Power supply

5 V

Power con-
sumption

0 W, in an extinguishing 
situation 5 W

Fire extin-
guishing agent

0,4 l Fettex, a class F fire 
extinguishing agent

Dimensions

70 x 70 x 350 mm

Service cycle

5 years

The fire 
extinguishing 
agent’s service 
life

10 years

8. CE-CONFORMITY

SAFERA Oy declares that SAFERA Siro is 
compliant to the following EU directives 
and standards::

EN 50615 category B and AB (55 cm 
installation height, 4 plates 60 cm cooker), 
2006/95/EC, 2004/108/EC, 1999/5/
EC, 2002/95/EC, 2002/96/EC, EN 301 
489-1: 2011 (V1.9.2), EN 301 489-17: 
2009 (V2.1.1), EN 55014-1:2000 / CISPR 
14-1, EN 55014-2:1997 / CISPR 14-2 + 
Amd.2, ETSI EN 300 328: 2012 (V1.8.1), 
EN 60730-1: 2000 + A12 + A13 + A1 + 
A14 + A16 + A2, EN 60730-2-9: 2010, EN 
60335-1: 2010 (ed 5.0), EN 60335-2-31: 
2002 / A1:2006.

Vantaa Finland 1.5.2015, Henri Andell, VD