12
7. SPECIFICATIONS
Central Unit
Power supply 230 V
∼
1 N, 47–60 Hz
Output voltage of the
power source 5 V 1 A
Power con-
sumption
1 W
Wireless con-
nection
SAFERA RobustLink 2,4
GHz. Range 10 – 100 m,
depending on the build-
ing structure
Pollution
degree
2
Power Control Unit
Compatibility Most electric cookers
and hobs used in private
homes.See specific
compatibility on the label
of the power control
unit
Ⓒ.
Power supply See the label of the
power control unit
Ⓒ.
Power con-
sumption
2 W
(PCU6.3 = 4 W)
Control type
According to IEC/EN
60730 - 1 : Type 1.B
Pollution
degree
2
Impulse volt-
age rating
4 kV
Operational
ambient tem-
perature
See the label of the power
control unit
Ⓒ.
Ball pressure
test rating
100 °C
PTI of insula-
tion materials
175...400
Designed
number of
automatic
actuations
6000
IP class
See power control unit
Extinguisher Unit
Compatibility
Typical cooktop fires,
including grease fires
Power supply
5 V
Power con-
sumption
0 W, in an extinguishing
situation 5 W
Fire extin-
guishing agent
0,4 l Fettex, a class F fire
extinguishing agent
Dimensions
70 x 70 x 350 mm
Service cycle
5 years
The fire
extinguishing
agent’s service
life
10 years
8. CE-CONFORMITY
SAFERA Oy declares that SAFERA Siro is
compliant to the following EU directives
and standards::
EN 50615 category B and AB (55 cm
installation height, 4 plates 60 cm cooker),
2006/95/EC, 2004/108/EC, 1999/5/
EC, 2002/95/EC, 2002/96/EC, EN 301
489-1: 2011 (V1.9.2), EN 301 489-17:
2009 (V2.1.1), EN 55014-1:2000 / CISPR
14-1, EN 55014-2:1997 / CISPR 14-2 +
Amd.2, ETSI EN 300 328: 2012 (V1.8.1),
EN 60730-1: 2000 + A12 + A13 + A1 +
A14 + A16 + A2, EN 60730-2-9: 2010, EN
60335-1: 2010 (ed 5.0), EN 60335-2-31:
2002 / A1:2006.
Vantaa Finland 1.5.2015, Henri Andell, VD