10
FITTING THE LUBRICATION SYSTEM
The lubrication system can be used for horizontal drilling applications.
1. Mount the cooling tank on the side off the clamp system.
2. Connect the hose to the nipple on the spindle drive shaft.
In order to use the lubrication system, it must be filled with a sufficient amount of cutting fluid.
1. Make sure the flow regulator is closed;
2. Unscrew the cap;
3. Fill the container with cutting fluid;
4. Screw the cap back on.
WARNING:
Do not use the system in vertical or overhead drilling applications.
Only use Carbide tipped track drill bits, Regular drill bits make the drilling machine
work harder and depletes the battery quicker.
INSERTING AND REMOVING AN ACCESSORY
Remove the battery pack from the machine before any adjustments, conversions or servicing
are performed.
Do not use deformed or damaged tools. Before use, always check tools such as core
drills for deformities or damage.
Do not use accessories that have not been specified or recommended by Safetrack for this
machine. The ability to attach the accessory to your machine does not guarantee safe operation.
Securing or positioning a tool incorrectly can cause hazardous situations due to parts breaking or
being blown off.
If the tool is jammed: Press the RED switch “O” to switch off the motor unit.
Remove the annular cutter from the borehole.
The tool holder accepts annular cutters with a 19,05 mm Weldon shank with one or more flats.
WARNING:
The teeth of a cutter are very sharp and can be dangerous.