background image

PROPRIETARY INFORMATION 

The material contained herein constitutes proprietary and confidential information, and is the intellectual 

property of 

SAFETRAN SYSTEMS CORPORATION

 protected under United States patent, copyright and/or 

other laws and international treaty provisions. This information and the software it describes are for authorized 

use only, and may not be: (i) modified, translated, reverse engineered, decompiled, disassembled or used to 

create derivative works; (ii) copied or reproduced for any reason other than specific application needs; or (iii) 

rented, leased, lent, sublicensed, distributed, remarketed, or in any way transferred; without the prior written 

authorization of 

SAFETRAN SYSTEMS CORPORATION

.  This proprietary notice and any other associated 

labels may not be removed.  

 

TRANSLATIONS 

The manuals and product information of

 SAFETRAN SYSTEMS CORPORATION

 are intended to be 

produced and read in English. Any translation of the manuals and product information are unofficial and 

can 

be imprecise and inaccurate in whole or in part. 

SAFETRAN SYSTEMS CORPORATION

 does not 

warrant the accuracy, reliability, or timeliness of any information contained in any translation of manual or 

product information from its original official released version in English and shall not be liable for any losses 

caused by such reliance on the accuracy, reliability, or timeliness of such information.  Any person or entity 

who relies on translated information does so at his or her own risk. 

 

WARRANTY INFORMATION 

SAFETRAN SYSTEMS CORPORATION

 warranty policy is as stated in the current Terms and Conditions of 

Sale document.  Warranty adjustments will not be allowed for products or components which have been 

subjected to abuse, alteration, improper handling or installation, or which have not been operated in 

accordance with Seller's instructions.  Alteration or removal of any serial number or identification mark 

voids the warranty. 

SALES AND SERVICE LOCATIONS 

Technical assistance and sales information on 

SAFETRAN

 products may be obtained at the following locations: 

 

SAFETRAN SYSTEMS CORPORATION

 

 

SAFETRAN SYSTEMS CORPORATION

 

2400 NELSON MILLER PARKWAY

 

 

CALIFORNIA DIVISION

 

LOUISVILLE, KENTUCKY  40223

 

 

10655 7th STREET

 

TELEPHONE:

 

(502) 618-8800

 

 

CUCAMONGA, CALIFORNIA 91730

 

FAX: 

 

(502) 618-8810

 

 

TELEPHONE:

 

(909) 532-5300

 

SALES & SERVICE: 

 

(800) 626-2710

 

 

CUSTOMER SERVICE: 

(800) 793-7233

 

WEB SITE: 

http://www.safetran.com 

 

TECHNICAL SUPPORT: 

(800) 793-7233

 

 

 

 

FAX: (909) 

532-5400 

 

Safetran

®

 is a registered trademark of Safetran Systems Corporation. 

 

Summary of Contents for 3000 GCP

Page 1: ...V309 01E IN THE 80115 DATA RECORDER MODEL FOR MODEL 3000 GCP May 2002 Revised December 2008 DOCUMENT NO SIG 00 01 17 VERSION C Safetran Systems Corporation California Division 10655 7th Street Cucamonga California 91730 1 800 793 SAFE Copyright 2002 Safetran Systems Corporation ...

Page 2: ...ined in any translation of manual or product information from its original official released version in English and shall not be liable for any losses caused by such reliance on the accuracy reliability or timeliness of such information Any person or entity who relies on translated information does so at his or her own risk WARRANTY INFORMATION SAFETRAN SYSTEMS CORPORATION warranty policy is as st...

Page 3: ...t software version also appears as the second message displayed during event printout To observe the sticker it is necessary to remove the Data recorder module from the 3000 GCP case as follows Step 1 Set the 3000 GCP case POWER switch to the OFF position WARNING INTERRUPTING GCP POWER WILL ACTIVATE THE CROSSING TAKE NECESSARY PRECAUTIONS TO PROTECT PEDESTRIANS AND VEHICLES IN THE IMMEDIATE AREA S...

Page 4: ... Computer DOS compatible with CD drive RS 232 cable 9 pin female to 25 pin male Safetran provided software release disk Z224 9V333 A01B Software Upgrade Instructions document number SIG 00 01 17 Version C Static shielding bag Flash PROM revision sticker F UPGRADE PROCEDURE CAUTION THIS UPDATE WILL AUTOMATICALLY CLEAR ALL RECORDED DATA FROM MEMORY Step 1 Verify that GCP POWER switch is ON 9 309 01X...

Page 5: ... hard drive for example C Safetran Step 5 Exit to DOS Windows DOS shell or Command Prompt Step 6 At the C prompt type CD name of folder example CD safetran Step 6 1 Press the Enter key Step 7 At the prompt type LOADBOOT Step 7 1 Press the Enter key The Setup screen displays see figure 3 9V309f2 10 11 01 COM1 PORT 9 PIN RS 232 CONNECTOR 80115 SERIAL PORT 25 PIN RS 232 CONNECTOR HISTORY ENTER SYSTEM...

Page 6: ...tep 8 1 Set the Recorder Module CLEAR OFF PRINT toggle switch to the CLEAR position and hold then set the MS GCP POWER switch to ON Step 8 2 Continue to hold the CLEAR OFF PRINT toggle switch in the CLEAR position until a Downloading window appears briefly within the Setup screen see figure 4 Figure 4 Boot Program Downloading Window 115f4 tif 10 12 01 115f2 tif 10 12 01 Figure 3 Data Recorder Modu...

Page 7: ...ee figure 5 Step 9 Type Y A boot reburn program Downloading window appears in the Setup screen see figure 6 At completion of the boot reburn program download the Success window displays within the Setup screen see figure 7 Figure 5 Boot Program Update Dialog Box 155f4 tif 10 12 01 Figure 6 Boot Reburn Program Download Window 155f6 tif 10 12 01 ...

Page 8: ...ys see figure 2 Step 12 Set the MS GCP POWER switch to OFF Step 12 1 Set the Recorder Module CLEAR OFF PRINT toggle switch to the CLEAR position and hold then set the MS GCP POWER switch to ON Step 12 2 Continue to hold the CLEAR OFF PRINT toggle switch in the CLEAR position until a downloading window appears briefly within the Setup screen see figure 8 155f7 tif 10 12 01 Figure 7 Boot Program Upd...

Page 9: ...pdate dialog box displays within the Setup screen see figure 9 Step 13 Type Y A setup program Downloading window appears in the Setup screen see figure 10 155f8 tif 10 12 01 Figure 8 Setup Program Download Window 155f9 tif 10 12 01 Figure 9 Setup Program Flash Memory Update Dialog Box ...

Page 10: ...ify that checksum displayed in Setup screen circled on figure 11 is identical to checksum supplied with program disk This completes application software installation Step 15 Set the 3000 GCP case POWER switch to the OFF position 155f10 tif 10 12 01 Figure 10 Setup Program Download Window 155f11 tif 10 12 01 Figure 11 Setup Program Success Window ...

Page 11: ... Step 17 Refer to figure 1 and locate flash PROM U10 9V309 Step 18 Affix a 9V309 A01E flash PROM revision sticker to flash PROM U10 as shown in figure 1 Ensure that the new revision sticker covers the old revision sticker Step 19 Return the Data Recorder Module to the proper slot in the 3000 GCP case Ensure that the module is fully seated in the edge connector Step 20 Set the 3000 GCP case POWER s...

Reviews: