1 of 8
Document No.: SIG-00-01-17
Version: C
A. BACKGROUND
Safetran periodically releases enhanced application software for the 80115 Data Recorder module
used in the Model 3000 Grade Crossing Predictor. The following pages contain instructions for
upgrading the application software in the 80115 Data Recorder Module.
B. SOFTWARE RELEASE DISK, Z224-9V333-A01B
Product Name: 3000 GCP
Software Revision: A01E
Module Number: 80115
SW P/N: 9V309-A01E
Memory Device: 9V309 (U10)
9V309-A01E CRC: 8E7CBF05B22F
C. SOFTWARE VERSION IDENTIFICATION
The software version resident in the 80115 Data recorder module is recorded on a sticker placed
on flash PROM U10 of the Data Recorder module. The resident software version also appears as
the second message displayed during event printout.
To observe the sticker it is necessary to remove the Data recorder module from the 3000 GCP
case as follows:
Step 1
Set the 3000 GCP case
POWER
switch to the
OFF
position.
WARNING
INTERRUPTING GCP POWER WILL ACTIVATE THE
CROSSING. TAKE NECESSARY PRECAUTIONS TO
PROTECT PEDESTRIANS AND VEHICLES IN THE
IMMEDIATE AREA.
Step 2
Remove the 80115 Data Recorder Module from the 3000 GCP case and place on
static-shielding bag.
Step 3
Refer to figure 1 and locate flash PROM U10 (9V309).
A sticker on flash PROM U10 identifies the current Data Recorder software version.
Step 4
Return the Data Recorder Module to the proper slot in the 3000 GCP case. Ensure
that the module is fully seated in the edge connector.
Step 5
Set the 3000 GCP case
POWER
switch to the
ON
position.
Step 6
Set time and date as required.