EASY STAIR USER GUIDE
safetyplatforms.co.uk | 01924 420820 | info@safetyplatforms.co.uk
Introduction
This user guide is designed to ensure your Easy Stair is positioned and used in the appropriate and safest
manner.
Before assembly, please read the whole of this guide, if the system is passed on to another person they
should also receive these instructions.
Easy Stair is designed to provide safe easy access for construction and related operations.
Easy Stair does not comply with building regulations - it is therefore not suitable for public access or a perma-
nent means of access.
Safety
Easy Stair is designed to provide easy, safe access between fl oor to fl oor levels ranging from 2.65m to 3.05m
Do not use Easy Stairs where it appears unsuitable or for other purposes it is not designed for.
Easy Stair has a safe working load of 225kg uniformly distributed - Do not exceed this load.
During use
Inspect the system on a weekly basis for signs of damage.
Ensure the stairs are kept free from a build-up of substances (mud, etc.) which could cause a slip or fall haz-
ard.
Preparation
Ensure you are using the correct PPE equipment.
Inspection
Check that all components are available and are functioning correctly.
System comprises of main stair unit and two guardrail frames
Inspect components prior to use for signs of damage - do not use damaged components.
Note: If in doubt about anything, consult your line manager, safety advisor or Safety Platforms Ltd.
1. Positioning of stair unit
The Stair unit (excluding guardrails) weighs 25kg.
Consideration should be given as to whether one person or two shall carry the unit and lift it into position.
Considerations would include ground conditions and access into the property.
The upper end of the stair unit has an “L” shaped angle which should be seated fully and fi rmly onto the up-
per fl oor level.
2. Floor to Floor heiqht in excess of 2.75m
Where the fl oor to fl oor height is in excess of 2.75m a suitable timber packer to a maximum of 300mm high)
should be positioned under the full width of the bottom tread to ensure the treads are horizontal (front to
back). This timber should be of a suitable thickness to level the treads from front to back and be secured by
two screws through the bottom aluminium tread
3. Securinq the stair unit
Once the stair unit is in position it needs to be secured by means of 2no screws minimum of 4mm (8G) x
45mm chipboard screws through the aluminium angle at the top of the stairs into the fl oor on which it is
rested.
To allow safe access for an operative up the stairs to fi x these screws a second person should foot the stairs
to prevent any horizontal movement
4. Installing guardrails
To allow for safe movement up and down the stairs it is essential that guardrails are positioned to both sides
of the stair unit.
These guardrails prevent a fall from the stairs and also provide a hand hold if required whilst climbing / de-
scending the stairs.