instantly with the release of menu button. The LED indicator light next to the “S” or “L” 

point outs which reading is being viewed. If the menu button is held in for longer than 3 

seconds, the display doesn’t change. 

8.2.

 

 Test 

The test function is used to assess the audible alarm. 

Press and hold the menu button

 

for 5 seconds

. The alarm will ring 4 chirps as if it is in an alarm condition. Release the 

menu button once the alarm begins to ring. 

8.3.

 

Alarm Mute On/Off 

This function allows you to silence the audible alarm. While in an alarm condition, 

press 

and hold the menu button for 15 seconds

. As you surpass the test phase, the alarm 

will  ring  4  chirps.  The  display  will  then  read  “Aoff”.  Release  the  menu  button 

immediately  and  the  display  returns  to  normal  condition.  If  the  long-term  reading 

returns to controlled level, audible alarm will be reset to the on position.   If desired, the 
alarm can be reactivated by repeating the same process.  On reactivation of the alarm, 

the display will read “Aon”. 

8.4.

 

Reset/Clear Memory 

This  function  allows  you  to  clear  and/or  reset  the  memory  for  both  short–term  and 

long–term  readings.  This  is  a  mandatory  step  whenever  the  detector  is  moved  to  a 
different location.  

Press and hold the menu button for 20 seconds

.   The display will 

read “CL”.  Upon release of the menu button, the “CL” keeps flickering until the memory 

has been completely cleared.   Once the memory has been cleared, the display will read 

“—“ for 48 hours until enough sample has been obtained to provide an exact reading. 

8.5.

 

Calibration 

Note for Radon Measurement Professionals 

The U.S. Environmental Protection Agency (EPA), Radiation and Indoor Environments 
National Laboratory (R&IE) has approved this device for radon gas level measurement.   

If  you  are  a  licensed  radon  measurement  professional  using  this  device  for  home 

inspections,  etc.,  the  EPA  recommends  a  calibration  and  background  check  be 

performed annually.  

Summary of Contents for HS71512

Page 1: ...etector 3 Installation of the Detector 4 Areas to be Avoided 5 Display Features 5 1 Short Term Display 5 2 Long Term Display 6 Initial Start Up 7 Audible Alarm 8 Menu Button Operation 8 1 Long Term Short Term 8 2 Test 8 3 Alarm Mute On Off 8 4 Reset Clear Memory 8 5 Calibration 9 Error Messages 9 1 Err3 9 2 Err4 10 Specifications 11 One Year Warranty ...

Page 2: ...n your home if it s measured over the long term at 4pCi L or greater You can also visit the EPA web site at www epa gov iaq radon index html for more information 2 Placement of Radon Detector The Safety Siren Pro Series3 Radon Detector should be positioned in the lowest living area of your home in a location where it will be kept undisturbed The audible alarm should be able to be heard from those ...

Page 3: ...detector should also not be placed in kitchens laundry rooms closets or bathrooms 5 Display Features The Safety Siren Pro Series 3 Radon Detector s display is designed to notify the user about the radon gas levels on either a short term or long term basis and is updated every hour if there is a change in the levels Both long term and short term measurements are run simultaneously and can be access...

Page 4: ...es need to be taken for at least 2 days 48 hours before an accurate reading is displayed 7 Audible Alarm 4pCi L is the standard level set by the EPA as the threshold at which corrective action should begin to eliminate the radon problem within your home The detector will alarm in both long term and short term modes when Short term readings display 4pCi L or more for 30 consecutive days or Long ter...

Page 5: ...arm will be reset to the on position If desired the alarm can be reactivated by repeating the same process On reactivation of the alarm the display will read Aon 8 4 Reset Clear Memory This function allows you to clear and or reset the memory for both short term and long term readings This is a mandatory step whenever the detector is moved to a different location Press and hold the menu button for...

Page 6: ...Messages Every 24 hours this radon gas detector will do a self test If there is a failure in this self test an error message will appear on the display 9 1 Err3 Noise Error This error is normally from any kind of electrical noise interferences This error can be caused by fluorescent lights computers televisions or other electric items The detector needs to be moved to a different location which is...

Page 7: ... Environment 0 C 32 F to 40 C 104 F Storage Environment 20 C 4 F to 85 C 185 F Audible Alarm 85dB at 10cm The alarm beeps every hour in case the long term readings are 4 pCi L or more The alarm beeps in case the short term readings are 4 pCi L or more for 30 consecutive days The alarm can be muted anytime by the user Averaging Frequency Levels will be updated on the detector s display every hour S...

Page 8: ...paired or replaced free of charge to the original purchaser If you suspect that your detector is defective please follow the instructions found below Procedures for Warranty Service 1 You can contact Family Safety Products Inc by email at info fspi radon com or by postal mail to receive a return authorization RA number Any products returned without the RA number will be refused and returned to the...

Page 9: ...with the product Damaging or removal of the back cover Damage caused by failure to follow installation Consequential or incidental damages or expenses This limited period warranty is restricted to the provisions clearly stated above Implied warranties warranties of merchantability and or warranties of fitness for a particular use are excluded If any of this warranty is prohibited by federal state ...

Reviews: