Performance Review

Manufacturer

Category/Model

Light Loss

American Security Equip. Co. 

Select-a-strobe SL24W-153075

36% Light Loss

Faraday

2700

33% Light Loss

Gentex

See note below*

36% Light Loss

System Sensor

SS24110ADA

35% Light Loss

Polycarbonate Cleaning Instructions

Rinse with water to remove abrasive dust and dirt.  Wash with soap or mild
detergent, using a soft cloth.  Rinse once more, then dry with a soft cloth or
chamois.  Exercise caution when using water inside enclosure. Make sure unit
is completely dry inside before reassembling. (Do not use razor blades).

Specifications

Fan:

24 VDC, 90 mA

UL Recognized Component

Life:

5 Years Continuous Duty

WARNING: The polarity of the circulating fan is important as it only
rotates in one direction with red lead being positive.

Gasket:

Material:

Neoprene

Life:

5 Years 

!

*NOTE FOR GENTEX:

GES24 may be followed by W, R or P.

Silicone Laminate Heater:

STI-1229HTR-HAZ 110 VAC 50/60 Hz

UL Recognized Component

STI-1229HTR240-HAZ 240 VAC 50/60 Hz

UL Recognized Component

100 Watts 
Life: @ -10˚C (14˚F) ~ 70˚C (158˚F)

5 Years

Duty Cycle:  -40˚F (-40˚C)

53%

-70˚F (-57˚C)

71%

Polycarbonate Enclosure:

Flammability:

UL94 V-2

Wall Thickness:

0.2 in (5.1mm)

NEMA Rating:

4X, indoor and outdoor use

Hazardous Rating:

Class II Groups F&G Div. 2

and Class III locations 

Warranty:

Three year guarantee against breakage of 
polycarbonate in normal use (one year on electro 
mechanical and electronic components).

Summary of Contents for STI-1229HTR-HAZ

Page 1: ...mperature or environmental conditions exceed the operating range of fire strobe signaling devices Unit requires 24 VDC continuous for fan operation and 110 VAC or 240 VAC for heater as well as power f...

Page 2: ...ng appliances indoors and outdoors and in areas of direct weather exposure 2 When covering fire signaling appliances with the enclosure some light loss occurs Please follow the guidelines listed durin...

Page 3: ...ecognized Component Life 5 Years Continuous Duty WARNING The polarity of the circulating fan is important as it only rotates in one direction with red lead being positive Gasket Material Neoprene Life...

Page 4: ...naling wires must enter thru top conduit and remain separated per NFPA 70 NEC and local codes HIGH VOLTAGE WIRING Refer to Fig 2 5 Connect high voltage Make sure 110 or 240 VAC power is OFF Refer to h...

Page 5: ...h wire under heater assembly Fan must be mounted toward top of enclosure 10 Wire strobe using Teflon coated wire provided White Positive Black Negative and attach to the strobe mounting bosses on heat...

Page 6: ...E PWR FAN PWR TEMP WARNING SUPERVISOR _ _ FAN LOW TEMP WARNING STROBE 16 33VDC 600mA S LOW VOLTAGE CIRCUIT HIGH VOLTAGE CIRCUIT TERMINAL BLOCK TERMINAL BLOCK CHASSIS HEATER EOL DEVICE SUPPLIED BY CUST...

Page 7: ...T 1 PROVIDED SOLID CLEAR COVER WASHER 6 PROVIDED 8 32 x 3 4 in SOCKET CAP SCREW 6 PROVIDED LOW VOLTAGE ELECTRICAL ENTRY IN AREAS WHERE FREQUENT WASH DOWNS OCCUR WASHERS MAY BE USED TO STAND OFF ENCLOS...

Page 8: ...International Europe Ltd Unit 49G Pipers Road Park Farm Industrial Estate Redditch Worcestershire B98 0HU England Tel 44 0 1527 520 999 Fax 44 0 1527 501 999 Freephone 0800 085 1678 UK only E mail in...

Reviews: