LIFT MODEL VISION AS 300 Rev001
4-1
4
TECHNICAL CHARACTERISTICS
4.1
Technical features – Dimensions
MODEL
VISION AS 300
Capacity load daN
300
Maximum No. of persons allowed on board
3
Highest speed in operation
20 m/min
Mast maximum height
93.5 m
Height of lifting
86 m
Maximum
height
reachable
without
anchorages
during
mounting/dismantling operations
6m
Distance between two following points of anchorage
6m
Maximum wind force tolerated while operating
72Km/h
Maximum wind force tolerated during mounting/dismantling
operations
45Km/h
Maximum wind force tolerated with the machine disabled
164Km/h
Motor power KW
1x4,0KW
Supply voltage
230/400V
Exhaust brake power supply voltage
230V
Secondary circuit voltage
110V
Normal absorption
8,5A
Breakaway current absorption
48,5A
Number of self-braking motors
1
Weight at the base (fence included)
600 kg
Rack module
8
Leq noise level:
60daB(A)
Table 1 : General features
DETAIL
HEIGHT m
LENGTH m
WIDTH m
Vertical element dimensions
1,482
0,368
0,258
Elevator car overall dimensions
2,3
1,3
0,95
Base dimensions
1,05
1,0
Fence overall dimensions
1,58
1,73
Table 2 : Dimensions
Summary of Contents for VISION AS 300
Page 2: ......
Page 4: ......
Page 43: ...LIFT MODEL VISION AS 300 Rev001 7 4 Fig 7 1 Dimension...
Page 68: ...LIFT MODEL VISION AS 300 Rev001 12 1 12 WIRING DIAGRAMS Fig 12 1 Wiring diagram Power supply...
Page 69: ...LIFT MODEL VISION AS 300 Rev001 12 1 Fig 12 2 Wiring diagram Motor power supply...
Page 70: ...LIFT MODEL VISION AS 300 Rev001 12 2 Fig 12 3 Wiring diagram Emergency circuit...
Page 71: ...LIFT MODEL VISION AS 300 Rev001 12 3 Fig 12 4 Wiring diagram Auxiliary...
Page 72: ...LIFT MODEL VISION AS 300 Rev001 12 4 Fig 12 5 4 Wiring diagram Auxiliary PLC logo expans...
Page 73: ...LIFT MODEL VISION AS 300 Rev001 12 5 Fig 12 6 Auxiliary circuit...
Page 74: ...LIFT MODEL VISION AS 300 Rev001 12 6 Fig 12 7 Wiring diagram Connectors C1 C2 C3...
Page 75: ...LIFT MODEL VISION AS 300 Rev001 12 7 Fig 12 8 Wiring diagram Terminal box electric panel...
Page 76: ...LIFT MODEL VISION AS 300 Rev001 12 8 Fig 12 9 Wiring diagram Cable call floor...
Page 77: ...LIFT MODEL VISION AS 300 Rev001 12 9 Fig 12 10 Wiring diagram Floors call connection...
Page 78: ...LIFT MODEL VISION AS 300 Rev001 12 10 Fig 12 11 Wiring diagram Box floor call connection...
Page 79: ...LIFT MODEL VISION AS 300 Rev001 12 11 Fig 12 12 Wiring diagram Box Fencing connection...
Page 80: ...LIFT MODEL VISION AS 300 Rev001 12 12 Fig 12 13 Wiring diagram Cable fancing call...
Page 81: ...LIFT MODEL VISION AS 300 Rev001 12 13 Fig 12 14 Main electrical box components...
Page 82: ...LIFT MODEL VISION AS 300 Rev001 12 14 Fig 12 15 Material list 1...
Page 83: ...LIFT MODEL VISION AS 300 Rev001 12 15 Fig 12 16 Material list 2...