Quantum™ MT™ Installation Instructions
Pg. 7 of 8
Testing Lock Functionality
Testing Lock Functionality
Insert a Construction keycard in the keycard reader. Be sure that the green light flashes for five seconds
while the exterior lever remains operable. If the green light does not flash, refer to the table below.
Insert a Construction keycard in the keycard reader. Be sure that the green light flashes for five seconds
while the exterior lever remains operable. If the green light does not flash, refer to the table below.
Lock Communication
Electronic Function Description
Red and green LEDs flash
Time and date not set, use the LPI to reset time and date
nine times simultaneously
Yellow LED flashes 12 times
Dead bolt is thrown or switch cam is not properly aligned
Yellow LED flashes two times
Keycard not allowed OR keycard cancelled by new keycard
Red and green LEDs flash
Low battery (contact the SAFLOK service department)
alternately nine times
Yellow and red LEDs flash
Bad keycard read or corrupted data (may require new
two times simultaneously
keycard)
Red LED flashes two times
Keycard not read (keycard inserted upside-down, wrong end,
wrong key?)
© SAFLOK™
INS_QTMCARDMT
2/16/2012