background image

Quantum™ MT™ Installation Instructions 

Pg. 8 of 8 

© SAFLOK™ 

INS_QTMCARDMT 

 2/16/2012 

SAFLOK Door Unit Inspection Criteria 

 

Appearance 

 

Finish is free of blemishes or scratches that would distract from lock appearance 

 

Lock body and under plate (if used) are mounted straight on the door 

 

Door scalp is mounted straight and flush with the door edge 

 

Jamb strike is mounted straight and is flush with the jamb face 

 

Correction of minor blemishes on the door jamb are the responsibility of the property’s maintenance 
department 

 

Lock Function 

 

Knob or lever rotates and moves freely 

 

Lever is horizontal to floor when at rest position 

 

Dead bolt extends fully and retracts without binding (door open) 

 

Lock latch and dead bolt engage jamb strike plate freely 

 

Anti-pick latch when depressed (door open) 

 

Anti-pick latch is depressed when contact is made with the strike plate (door closed) 

 

Electronics/Keycards 

 

Keycard can be inserted and withdrawn freely 

 

Yellow light flashes twice when incorrect keycard is used  

 

Red light flashes twice if keycard is used incorrectly and cannot be read  
(e.g., a credit card is used) 

 

Green light flashes when the proper keycard is used 

 

Green light is flashing when the lever is operated 

 

Green light continues to flash for a five-second cycle 

 

Yellow light flashes 12 times when the dead bolt is extended and a guest/hotel  
keycard is used 

 

All keycards function to the specifications of the master plan 

 

Door function 

 

Door closes and latches with little or no interference 

 

Dead bolt extends fully through the strike plate without interference (door closed) 

 

Spacing between door edge and inside door jamb does not exceed 3/16” (door closed) 

 

Note:

 If bumpers or other seals are added after strike plate installation and causes alignment and latch 

problems, it is the property’s responsibility to correct this condition. This note generally applies to new 
construction or new door installation. 
 

 
 

Questions? 

Call Customer Service at 800.999.6213 and select option 3. 
For online assistance, visit support.saflok.com. 

Summary of Contents for Quantum MT

Page 1: ...6 XX Card Reader Assembly A20950 COLOR Rubber Gaskets external applications only Screw Pack A29070 COLOR All information contained herein including but not limited to product pricing and other intelle...

Page 2: ...appropriate for the SAFLOK mortise lock Drill fixture If you are using a SAFLOK drill fixture position and clamp the fixture on the door The fixture has two positioning posts that rest inside the mort...

Page 3: ...into the pocket 4 Attach the mortise front plate to the door using the two mortise screws 12 x 1 1 4 screws for wood doors 12 24 x 3 8 screws for metal doors Be sure that the screws are fully tightene...

Page 4: ...cable through the reader cutout in the door 3 Position the inside trim on the inside of the door 4 Secure inside trim to the card reader assembly using three 8 32 x 1 1 4 screws Important Do not full...

Page 5: ...B mortises or at the bottom 6 00 position for standard mortises see Fig 3 The retaining ring should rest on the switch cam when fully inserted the proper positioning of the cam will allow the door to...

Page 6: ...6mm Torx Screws Fig 4 14 Program the lock using the Lock Programmer and Interrogator LPI probe Test the functioning of the lock as discussed in the following section and in the programming manual befo...

Page 7: ...h refer to the table below Lock Communication Electronic Function Description Red and green LEDs flash Time and date not set use the LPI to reset time and date nine times simultaneously Yellow LED fla...

Page 8: ...nserted and withdrawn freely Yellow light flashes twice when incorrect keycard is used Red light flashes twice if keycard is used incorrectly and cannot be read e g a credit card is used Green light f...

Reviews: