MorphoSmart™ Fingerprint scanners Installation Guide
MorphoSmart
™ device Technical Characteristics
SSE-0000080361-05
May 2015
This document and the information therein are the property of Morpho. They must not be
copied or communicated to a third party without the prior authorization of Morpho
33
11.2.4 Identify performances
The identify process compare the search fingerprint to all the records of the database.
The identify process compare first the search fingerprint to the 1
st
fingerprint (fingerprint
#1) of each database record. If a match is found, the comparison process stops, else, the
identify process compare the search fingerprint to all 2nd fingerprint (fingerprint #2) of
each database record.
It means that the identification process is faster when the user place on the sensor, a
finger which is recorded as the 1st fingerprint of the user’s record. It also means that the
time required to reject a fingerprint (No Hit) is higher than the time required to match
with the 1st fingerprint of a record.
Number of records
Hit fingerprint # 1
Hit fingerprint # 2
No Hit
100
≤ 1 s
≤ 1.5 s
≤ 1.5 s
500
≤ 1.1 s
≤ 1.5 s
≤ 1.5 s
2000
≤ 1.5 s
≤ 2 s
≤ 2 s
3000
≤ 2 s
≤ 2.5 s
≤ 2.5 s
5000
≤ 2.5 s
≤ 3 s
≤ 3 s
Table 6: Identify performances
Please not that:
The measure starts with finger valid placement on the sensor and stops with result
returned to the host system.
the time value is intended for typical fingerprints : more characteristic points per
fingerprint (such as for a thumb fingerprint) means more time.
Add 1 second to ‘no hit’ time when ‘advanced matching’ is used (please refer to the
definition of ID_Matching_Strategy optional ILV in ‘MorphoSmart™ Host System
Interface specifications’ document)
The time value can be multiplied by 2 when ‘not oriented matching’ is used (please
refer to the definition of value 2 for Sensor_Window_Position ILV definition in
‘MorphoSmart™ Host System Interface specifications’ document).