MorphoSmart™ Fingerprint scanners Installation Guide
Man Machine Interface
SSE-0000080361-05
May 2015
This document and the information therein are the property of Morpho. They must not be
copied or communicated to a third party without the prior authorization of Morpho
34
12. Man Machine Interface
12.1 MSO2xx/MSO3xx Man Machine Interface
12.1.1 Description
In addition to the sensor light, there are two LEDs to provide information to the user:
when the sensor light is on, it usually means that the device is waiting for the user to
place a finger on the sensor,
the upper led is mainly used for smart card reader status (MSO35x only),
the lower led is mainly used for biometric process status.
The tables below describe the meaning of the light signals.
12.1.2 Biometric terminal status
Status
Sensor
Lower LED
Upper LED
Suspend (low power mode)
Off
Off
Off
Stand By (wait for a request)
Off
Flashing Green
See Table
Maintenance State (such as
firmware update in progress)
Off
Blinking Red
Blinking Red
Personalization State (secure MSO)
Off
Blinking Red
Blinking Red
Unrecoverable Error or USB
enumeration Error (see note)
Off
Red
Red
Table 7: MSO20x/MSO3xx status
NOTE: Both LEDs are red from successful power-up until the USB device is successfully
enumerated by the host system (usually a few seconds).
12.1.3 Biometric process status
Status
Sensor
Lower LED
Waiting For Finger
On
Off
Waiting For Finger Removal
On
Green
Finger Misplaced Or Latent
On
Blinking Red
Switch To Next Finger (enroll process)
On
Blinking Green
Recognized Finger
Off
2 seconds in Green
Finger Unknown / Failure
Off
2 seconds in Red