background image

 

 

 

Sage Water Dispenser 

Instruction Manual 

 

 

 

 

 

 

 

SAGE WATER COOLERS 

 

 

 

 

Please read this manual carefully before using! 

 

CONTENTS 

 

1. Brief Introduction of The Machine 

 

(1) Brief Introduction of the Appearance   

(2) Touch panel Introduction 

 

2. Technical Parameter 

 

3. Installation

 

(1) Overview 

(2) Water supply connection 

 

4. Operation

 

(1) 

I

nitially connected to electrical source 

(2) First time Operation 
(3) Operating the dispenser 
(4) Setting parameter options 

 

5. Machine maintenance and parts replacement

 

1. Replacing parts 
2. Clear airframe 

 

6. FAQ

 

   

7. Trouble Shooting 

 

 

 

 

Summary of Contents for SAGECRDM

Page 1: ...troduction of the Appearance 2 Touch panel Introduction 2 Technical Parameter 3 Installation 1 Overview 2 Water supply connection 4 Operation 1 Initially connected to electrical source 2 First time Operation 3 Operating the dispenser 4 Setting parameter options 5 Machine maintenance and parts replacement 1 Replacing parts 2 Clear airframe 6 FAQ 7 Trouble Shooting ...

Page 2: ...itch 3 Drip tray 11 Water Inlet Whole 4 2 8 TFT LCD screen 12 Switch Panel 5 Faucet 13 Fan 6 Panel 14 Fuse 7 Drain tray 15 Power Switch 8 Decorative Panel 16 Power Cord 2 Touch Panel Introduction 1 Day Month Year 2 Child Lock status icon 3 UV light status icon 4 Hot key and select key 5 Heating and hot water temperature icon 6 Extra hot Key ...

Page 3: ...s and parameters without notice and without incurring any obligations or liabilities for such changes Item Specification Parameter 1 Electricity features Rated Voltage Frequency Rated Power Rated Current 110 VAC 60 Hz 620 W 6A 2 Heating system Rated Heating Power Heating Capability Hot Water Temperature 500 W 5L H 194 205 F Adjustable 3 Cooling system Rated Cooling Power Rated Cooling Current Cool...

Page 4: ...ny original settings 2 Water Supply Connection Please keep the machine in a place nearby the water supply not more than 3 Meters water pressure should be configured with between 0 1 MPa and 0 6MPa A Connect the inlet Picture 1 to be sure there is no leakage Picture 1 Picture 2 B Twist the valve to ensure air tightness when connecting C Please remove the cover of the inlet water connector and block...

Page 5: ...r flowing out of hot and cold water outlet 2 Attentions Before Using First time using the unit please check all water pipe fittings and valve connections making sure they are well connected After tuning on the unit please release 10 15L of water out of both the hot and cold reservoirs Safety Warning For first time to use please ensure that there is water flowing out from the faucet in hot and cold...

Page 6: ...switch at back of the machine to the ON position the heating system will begin to work then hot water icon will be dynamically displayed in the screen accordingly Touch for 0 5second and it will enter into the re boiling condition B Cold water Touch will produce cold water touch any key to stop the water flow C Warm Water Touch for mixed hot cold water touch any key to stop the water flow D Get On...

Page 7: ...gs ring settings and restore factory settings Press to toggle and press to enter the selected interface Press to go back to last interface press and select specific parameters B Temperature Settings Select the temperature setting item enter into temperature control interface then follow the prompts to set parameters as follows C Water Quantity Settings Select water quantity setting enter into the ...

Page 8: ...rs as follows Then press to save parameters E Energy Saving Mode Select energy saving mode enter into power saving mode adjustment Interface and follow the prompts to set parameters as follows Sleep Mode When the machine goes into sleep mode it appears as Automatic On Off Switch Standby mode will appear similar to screen below Press any key ...

Page 9: ...s to set parameters as follows G Filter UV Maintenance Settings Select Filter UV maintenance setting item enter into the filter UV maintenance adjustment interface and follow the prompts to set parameters as follows Maintain the Filter Mode Maintain the UV Mode H Language Settings I Ring Settings J Restore Factory Settings ...

Page 10: ...he filter anticlockwise change CLOSE install the filter clockwise installation Enter into the setting mode after replacing the filter filter UV maintenance filters filter replacement and press Confirm B UV Maintenance UV should be replaced once a year When the UV lamp is reaches its lifetime the unit will remind you to replace the UV lamp Check the accessory of the unit you will find a UV replacem...

Page 11: ...me or cleaned please ensure there is water flowing out and then open the heating function to avoid equipment damage The system provides safe and reliable drinking water Since the tank is not pressurized and hot tank with outlet of hot water is directly connected no valves it is normal if a drop of water results after water flow Because the unit can produce high temperature hot water please refrain...

Page 12: ...r 10 minutes Follow the prompts to open the system restore function within 3 minutes No cold water Chilled water temperature set too high Excessive cold water use Check the water temperature settings Test again after 30 minutes Turn off the power wait 2 hours before Long term of not using cold water tank frozen turning on power use Machine leaking Drip tray is full Leakage inside of the machine Em...