12.Maintenance and cleaning

It is absolutely essential that  the fixture  is  kept clean and  without  dust. Dirt 

and  smoke - fluid   residues   must   not  be  covered  on  or  within  the  fixture.

Otherwise, the   fixtures  light  output  will  be  significantly  reduced.  Regular 

cleaning will not onlyen sure  the maximum light-output, but will also allow the 

fixture  to  function reliably  throughout its life.A soft  lint-free cloth moistened.

With  any good glass cleaning  fluid  is  recommended, under no 

 alcohol or solvents be used!

DANG ER :Disconnect from the mains before starting any maintenance work.

The front  objective lens  will  require weekly cleaning as  smoke-fluid tends to 

building up residues,reducing the light-output  very  quickly. The cooling -fans 

should be cleaned monthly.

The gobos may be cleaned with a soft brush.the interior  of  the  fixture  should 

be cleaned at least annually usinga vacuum-cleaner or an air-jet.

The dichroic colour-filters,the gobo-wheel  and the internal lenses  should  be 

cleaned monthly.

to ensure a proper  function of  the  gobo-wheel,we  recom mend  lubrication in 

six month intervals.The quantity of  oil must not be  excessive in order to avoid 

that oil runs out when the gobo-wheel rotates.

 

There are no serviceable parts inside  the  device  except  for the lam pand the 

fuss. Please   refer   to   the  instructionsunder 

Fitting/Exchanging the lamp

.

Main tenance  and  service  operations  are  only to be carried out by  authorze

dealers.

Replacing  the fuse 

If  the lamp bums out,the fuse might of  fails  might fuse, too. Only  replace  the  

fuse by of same type and rating. Before replacing the fuse, unplug mains lead.

circumstance 

of

17

Summary of Contents for ARROW300B

Page 1: ...ARROW300B USER S MANUAL PROEL GROUP BRAND Sagitter com MOVING HEAD...

Page 2: ...mance trait 16 12 Maintenance and cleaning 1 7 1 1Safety Instructions Open the box and checking Important 7 Operating determinations 6 Rigging the fixture Control menu map 1 Description of the device...

Page 3: ...1 Description of Device 3 1 HEAD 2 ARM 3 BASE 4 POWER SWITCH 5 POWER IN 6 FUSE 7 FUSE 8 5 PIN DMX OUT 9 5 PIN DMX OUT 10 3 PIN DMX OUT 11 3 PIN DMX IN...

Page 4: ...an cause injuries or damages 4 The system doesn t contain any maintainable parts Don t open it 5 It is necessary to wait at least 15minutes after disconnecting the AC before changing the optical carri...

Page 5: ...nd minstallation is assured You will find special connectors on the bottom side of the system which are put to use here In additioin the front side of the system i s marked with FRONT as this is impor...

Page 6: ...This product uses Philips MSR GOLD300 2 fast fit electrical arc lamp When receiving this product please carefully bring and put and check whether this equipment has been damaged or not during transpor...

Page 7: ...essable after installing the device Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time Always disconnect from the mains when...

Page 8: ...tion place is blocked when rigging dragging or servicing the fixture Always fix the fixture with an appropriate safety rope Fix the safety rope at the correct holes only Operation thefixture after hav...

Page 9: ...ms have be used The proj ector must never be fixed swinging freely In the room Caution projectors may cause severe injuries when crashing down if you have doubts concerning the safety of a possible in...

Page 10: ...PROEL GROUP BRAND 7 Dimension 10 Mounting plate...

Page 11: ...n International Brown Liht blue Yellow Green Black White Green Live Neutral Earth L N DMX 512 connection connection between fixtures Only use a stereo shielded cable and 3 pin XLR plugs and connectors...

Page 12: ...194 255 Color wheel 6 4 Rot gobo 1 Rot gobo 2 Rot gobo 2 Rot gobo 4 Rot gobo 5 Rot gobo 6 Rot gobo 7 Gobo 1 shake slow to fast Gobo 2 shake slow to fast Gobo 3 shake slow to fast Gobo 4 shake slow to...

Page 13: ...1 32 63 64 155 156 163 164 255 No Function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro 13 Macro 14 Macro 15 13 13 15 15 Effect Scene 0 15 1...

Page 14: ...0 to 100 Colour change normal Colour change linear No function Lamp switch off All motor reset Scan motor reset Colors motor reset Gobo motor reset Shutter Dimmer motor reset Other motor reset Intern...

Page 15: ...ization Feedback Mic Sensitivity Status Settings DMX Mode Fans Control Display Set Temperature C F Language choose Reset Default Reset All Reset Pan Tilt Reset Color Reset Gobo Reset Pins Reset Else R...

Page 16: ...l triple prism system 4 Zoom and focus system 5 22DMX Chs 6 Frost Linearity 7 lris Linearity adjust pulse variation 8 Strobe two motor strobe synchronous non synchronous random strobe effect 9 Blue wh...

Page 17: ...kly The cooling fans should be cleaned monthly The gobos may be cleaned with a soft brush the interior of the fixture should be cleaned at least annually usinga vacuum cleaner or an air jet The dichro...

Page 18: ...PROEL GROUP BRAND 18...

Page 19: ...19...

Page 20: ...GOGOS WHEEL GEAR MOTOR 33 SH40 1 1 1 1 1 1 1 1 1 1 1 4 1 1 1 1 3 1 2 1 1 1 1 2 1 7 1 1 SGVP00037 SGTA00066 SGGM00036 SG013 039 SGTA00069 SGEE00033 SGGM00037 SGEE00034 SG013 039 SG013 040 SGMO00034 SGV...

Page 21: ...21...

Page 22: ...SHAFT LOWER YOKE PLATE PAN LOCK SHAF HOLDER PLATE REINFORCEMENT PLATE CODE SGFP00036 SGEE00036 SG013 058 SGMO00036 SG031 059 SGVP00042 SG013 030 SGVP00043 SGTA00073 SGVP00044 SGVP00045 SGTA00074 SG013...

Page 23: ...23...

Page 24: ...HOLDER PLATE PCB SENSOR PAN MOVEMENT PLATE N PCS 2 2 2 2 1 2 1 1 1 1 2 1 1 1 1 2 2 2 1 1 1 2 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 SG013 070 SGTA00081 SGVP00047 SGGM000...

Page 25: ...PROEL S p A World Headquarters Factory Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 Sagitter com...

Reviews: