6. Rigging the fixture

        DANGER TO LIFE  Please consider the respective national norms during the installation! 

        The installation must only be carried out by an authorized dealer!

 

    The  installation  of  the  projector has to be built and  constructed in a  way that can  hold

        10 times the weight for 1 hour without any harming deformation.

 

    The installation must always  be  secured  with  a  secondary  safety  attachment,  e.g.an 

        appropriate catch net. This secondary safety  attachment must  be  constructed  in a way 

        that no part of the installation can fall if the main attachment fails.

 

    When rigging, dragging or servicing the fixture staying  in  the  area below the installation 

        place, on bridge, under high working place and other endangered area is forbidden.

 

    The operator has to make sure that  safety-relating   and  machine-technical  installations 

        are   approved  by  an  expert  before  taking  into  operation   for  the  first  time  and  after 

        changes before taking into operation another time.

 

    The operator  has  to  make  sure that  safety-relating and machine-technical installations 

        are approved by an expert after  every four year in the course of an  acceptance test.

 

    The projector has to be installed out reach of people.

 

    If  the   projector   shall   be   lowered   form   the   ceiling  or  high  joists, professional  

         trussing systems  have  be used. The  proj ector must  never  be fixed swinging freely

         In   the room.

 

    Caution projectors may cause  severe injuries  when   crashing d

  own!i f y ou h ave d oubts  

        concerning the safety of a possible installation, do NOT install the projector!

 

    Before  rigging  make sure that the installation area  can hold a minim  um  point  load 

         of  10  times the projectors weight.

 

    The projector can be placed directly on the stage floor or rigged  in any orientation  on 

         a trus without altering its operation characteristics.

 

    For  overhead  use, always  install  a  safety-rope  that  can  hold at least 10 times  the 

         weight  of  the  fixture. You must only use safety-ropes with  screw  on  carabines. Pull  

         the  safety-rope  through  the  two  apertures  on  the  bottom of the base and over  the

         trussing  system  etc.

 

    Insert the end in the carabine and tighten the fixation screw.

 

    IMPORTANT: OVERHEAD RIGGIG REQUIRES EXTENSIVE EXPERIENCE, 

         including(but not limited to)   calculating  working  load  limits,  installation   material  

         being used   and   periodic   safety   inspection   of   all  installation  material  and  the 

         projector. If you lack  these  qualifications, do  not  attempt  the  installation yourself, 

         but instead using  a professional structural rigger.Improper installation can  result in 

         bodily  injury or damage to property. 

 

     The   operator   has   to  make   sure    that    safety-relating   and    machine-technical  

         installations are approved by a skilled person once a year.

 

     The projector should be installed outside  areas  where  persons  may  walk  by  or  be 

         seated.

9

Summary of Contents for ARROW300B

Page 1: ...ARROW300B USER S MANUAL PROEL GROUP BRAND Sagitter com MOVING HEAD...

Page 2: ...mance trait 16 12 Maintenance and cleaning 1 7 1 1Safety Instructions Open the box and checking Important 7 Operating determinations 6 Rigging the fixture Control menu map 1 Description of the device...

Page 3: ...1 Description of Device 3 1 HEAD 2 ARM 3 BASE 4 POWER SWITCH 5 POWER IN 6 FUSE 7 FUSE 8 5 PIN DMX OUT 9 5 PIN DMX OUT 10 3 PIN DMX OUT 11 3 PIN DMX IN...

Page 4: ...an cause injuries or damages 4 The system doesn t contain any maintainable parts Don t open it 5 It is necessary to wait at least 15minutes after disconnecting the AC before changing the optical carri...

Page 5: ...nd minstallation is assured You will find special connectors on the bottom side of the system which are put to use here In additioin the front side of the system i s marked with FRONT as this is impor...

Page 6: ...This product uses Philips MSR GOLD300 2 fast fit electrical arc lamp When receiving this product please carefully bring and put and check whether this equipment has been damaged or not during transpor...

Page 7: ...essable after installing the device Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time Always disconnect from the mains when...

Page 8: ...tion place is blocked when rigging dragging or servicing the fixture Always fix the fixture with an appropriate safety rope Fix the safety rope at the correct holes only Operation thefixture after hav...

Page 9: ...ms have be used The proj ector must never be fixed swinging freely In the room Caution projectors may cause severe injuries when crashing down if you have doubts concerning the safety of a possible in...

Page 10: ...PROEL GROUP BRAND 7 Dimension 10 Mounting plate...

Page 11: ...n International Brown Liht blue Yellow Green Black White Green Live Neutral Earth L N DMX 512 connection connection between fixtures Only use a stereo shielded cable and 3 pin XLR plugs and connectors...

Page 12: ...194 255 Color wheel 6 4 Rot gobo 1 Rot gobo 2 Rot gobo 2 Rot gobo 4 Rot gobo 5 Rot gobo 6 Rot gobo 7 Gobo 1 shake slow to fast Gobo 2 shake slow to fast Gobo 3 shake slow to fast Gobo 4 shake slow to...

Page 13: ...1 32 63 64 155 156 163 164 255 No Function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro 13 Macro 14 Macro 15 13 13 15 15 Effect Scene 0 15 1...

Page 14: ...0 to 100 Colour change normal Colour change linear No function Lamp switch off All motor reset Scan motor reset Colors motor reset Gobo motor reset Shutter Dimmer motor reset Other motor reset Intern...

Page 15: ...ization Feedback Mic Sensitivity Status Settings DMX Mode Fans Control Display Set Temperature C F Language choose Reset Default Reset All Reset Pan Tilt Reset Color Reset Gobo Reset Pins Reset Else R...

Page 16: ...l triple prism system 4 Zoom and focus system 5 22DMX Chs 6 Frost Linearity 7 lris Linearity adjust pulse variation 8 Strobe two motor strobe synchronous non synchronous random strobe effect 9 Blue wh...

Page 17: ...kly The cooling fans should be cleaned monthly The gobos may be cleaned with a soft brush the interior of the fixture should be cleaned at least annually usinga vacuum cleaner or an air jet The dichro...

Page 18: ...PROEL GROUP BRAND 18...

Page 19: ...19...

Page 20: ...GOGOS WHEEL GEAR MOTOR 33 SH40 1 1 1 1 1 1 1 1 1 1 1 4 1 1 1 1 3 1 2 1 1 1 1 2 1 7 1 1 SGVP00037 SGTA00066 SGGM00036 SG013 039 SGTA00069 SGEE00033 SGGM00037 SGEE00034 SG013 039 SG013 040 SGMO00034 SGV...

Page 21: ...21...

Page 22: ...SHAFT LOWER YOKE PLATE PAN LOCK SHAF HOLDER PLATE REINFORCEMENT PLATE CODE SGFP00036 SGEE00036 SG013 058 SGMO00036 SG031 059 SGVP00042 SG013 030 SGVP00043 SGTA00073 SGVP00044 SGVP00045 SGTA00074 SG013...

Page 23: ...23...

Page 24: ...HOLDER PLATE PCB SENSOR PAN MOVEMENT PLATE N PCS 2 2 2 2 1 2 1 1 1 1 2 1 1 1 1 2 2 2 1 1 1 2 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 SG013 070 SGTA00081 SGVP00047 SGGM000...

Page 25: ...PROEL S p A World Headquarters Factory Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 Sagitter com...

Reviews: