background image

 
 
 

 
 

17 

 

 

Prism/gobo macros /prism - rotation 

128-135 

Macro 1 

136-143 

Macro 2 

144-151 

Macro 3 

152-159 

Macro 4 

160-167 

Macro 5 

168-175 

Macro 6 

176-183 

Macro 7 

184-191 

Macro 8 

192-199 

Macro 9 

200-207 

Macro 10 

208-215 

Macro 11 

216-223 

Macro 12 

224-231 

Macro 13 

232-239 

Macro 14 

240-247 

Macro 15 

248-255 

Macro 16 

15  11  21  13 

 

 

Prism rotation and indexing 

 

 

Prism indexing - set position on channel  
14/10/20/12 

0-255 

Prism indexing 

 

 

Prism  rotation - set position on channel 
14/10/20/12 

No rotation 

1-127 

Forwards prism  rotation from fast to slow  

128-129 

No rotation 

130-255 

Backwards prism  rotation from  slow to fast . 

16  12  22  14 

 

 

Frost  

Open  

1-179 

Frost from  0%-100% 

180-189 

100% frost 

190-211 

Pulse closing from slow to fast 

212-233 

Pulse opening from fast to slow  

234-255 

Ramping from fast to slow  

17  13  23  15 

 

 

Zoom 

0-255 

Zoom from max. to min. beam angle  

18 

24 

 

 

Zoom -fine 

0-255 

Reserved 

Summary of Contents for SG BLKARROW

Page 1: ...Moving Head Spot Beam 280W SG BLKARROW MANUALE UTENTE USER MANUAL...

Page 2: ...INSTALLAZIONE ED ACCENSIONE p 7 5 ISTRUZIONI PER L USO p 9 6 MANUTENZIONE p 19 7 SPECIFICHE TECNICHE p 20 INDEX 1 INTRODUCTION p 21 2 SAFETY INSTRUCTIONS p 22 3 OPENING AND CONTROL p 24 4 INSTALLATIO...

Page 3: ...te a separare questo prodotto da altri tipi di rifiuti e di riciclarlo in maniera responsabile per favorire il riutilizzo sostenibile delle risorse materiali Gli utenti domestici sono invitati a conta...

Page 4: ...odotto Il cavo di sicurezza deve essere debitamente agganciato al dispositivo e fissato alla struttura di sostegno in modo che in caso di cedimento del sistema di supporto primario si abbia la minore...

Page 5: ...anche la potenza assorbita a cui necessario fare riferimento per valutare il numero massimo di dispositivi da collegare alla linea elettrica al fine di evitare sovraccarichi Se il cavo di alimentazio...

Page 6: ...TTENZIONE Se l apparecchio stato esposto a drastici sbalzi di temperatura lasciare spenta l unit finch non raggiunge la temperatura ambiente in quanto la presenza di condensa potrebbe danneggiare il p...

Page 7: ...L unit pu essere installata a pavimento in appoggio sugli appositi piedini in gomma a parete a soffitto o su truss ATTENZIONE E OBBLIGATORIO il montaggio della fune di sicurezza PLH200 venduta separat...

Page 8: ...rogettato come indicato nella targhetta dei dati elettrici 4 3 COLLEGAMENTO ALLA CATENA DMX Utilizzare un cavo conforme alle specifiche EIA RS 485 bipolare intrecciato schermato 120Ohm di impedenza ca...

Page 9: ...Lamp Temp Power On Time Total Hours Resetable Hours Lamp On Time Total Hours Resetable Hours Lamp Strikes Total Strikes Resetable Strikes Personality Display Adjusting Display Permanent On ON OFF Disp...

Page 10: ...n Tilt Moving ON OFF Colour Wheel Moving ON OFF Gobo Wheels Moving ON OFF Dimmer Curve curve1 curve 2 Default Setting Lamp On OFF On Off Test sequences Mode 1 Pan 0 255 Tilt 0 255 Zoom 0 255 Focus 0 2...

Page 11: ...nd copy Start Step 1 99 End Step 1 99 Reset functions Reset All Pan Tilt Focus Zoom Prism Special functions Lamp Adjustment Pan 0 255 Tilt 0 255 Zoom 0 255 Focus 0 255 Effect Adjustment DMX Values Pan...

Page 12: ...lt speed mode 1 255 Speed from max to min Pan Tilt time mode 1 255 Time from 0 2 s to 25 5 sec 6 4 6 6 Power Special functions 0 129 Reserved 130 139 Lamp on reset total reset except pan tilt reset 14...

Page 13: ...green 167 171 Amber 172 176 Blue 177 180 Orange 181 185 CTO 186 189 UV filter 190 215 Forwards rainbow effect from fast to slow 216 217 No rotation 218 243 Backwards rainbow effect from slow to fast...

Page 14: ...obo 3 22 27 Gobo 4 28 33 Gobo 5 34 39 Gobo 6 40 45 Gobo 7 46 51 Gobo 8 52 57 Gobo 9 58 63 Gobo 10 64 69 Beam reducer 1 70 75 Beam reducer 2 76 81 Beam reducer 3 82 87 Beam reducer 4 Shaking gobos from...

Page 15: ...hannel 12 9 18 11 0 Open Hole default 1 4 Hole flat field 5 7 Gobo 1 8 10 Gobo 2 11 13 Gobo 3 14 16 Gobo 4 17 19 Gobo 5 20 22 Gobo 6 23 35 Gobo 7 26 28 Gobo 8 29 31 Gobo 9 Rotation set rotation on cha...

Page 16: ...m slow to fast 244 255 Reserved 12 9 18 11 Rot gobo indexing and rotation Gobo indexing set position on channel 11 8 17 10 0 255 Gobo indexing Gobo rotation set position on channel 11 8 17 10 0 No rot...

Page 17: ...indexing Prism indexing set position on channel 14 10 20 12 0 255 Prism indexing Prism rotation set position on channel 14 10 20 12 0 No rotation 1 127 Forwards prism rotation from fast to slow 128 12...

Page 18: ...l lamp power 280W 64 95 Strobe effect from slow to fast 96 127 Shutter open 128 143 Opening pulse in sequences from slow to fast 144 159 Closing pulse in sequences from fast to slow 160 191 Shutter op...

Page 19: ...ressore e una spazzola morbida o un panno per lenti per rimuovere la polvere depositata Le lenti come qualsiasi altra parte eventualmente danneggiata devono essere sostituite con ricambi originali SOS...

Page 20: ...orbita 480W Modalit operative Auto Sound active Master slave DMX512 Ruota gobo 1 9 gobo rotanti intercambiabili con sistema plug play Ruota gobo 2 10 gobo fissi 4 steps beam reduce Ruota colori 13 col...

Page 21: ...to the environment the user is encouraged to separate this product from other kinds of wastes and recycle it responsibly to promote the sustainable reuse of material resources Home users are encourage...

Page 22: ...The safety cable must be properly attached to the device and fixed to the supporting structure so that in case of failure of the primary supporting system it has the lowest possible fall of the device...

Page 23: ...mption that is necessary to refer to evaluate the maximum number of devices to be connected to the electricity line in order to avoid power overloading If the external power cord of this light is dama...

Page 24: ...ARNING If the product has been exposed to drastic temperature changes let the unit turned off until it reaches room temperature because the presence of condensation can damage the product if it is tur...

Page 25: ...it fixing The unit can be installed on the floor resting on the rubber feet on the wall ceiling or on a truss WARNING IT S REQUIRED the mounting of the safety rope PLH200 sold separately in the case w...

Page 26: ...in the electrical data label 4 3 CONNECTION TO THE DMX CHAIN Use a cable conforming to specifications EIA RS 485 pole twisted shielded 120 Ohm characteristic impedance and low capacity PROEL DMXD DMX...

Page 27: ...r On Time Total Hours Resetable Hours Lamp On Time Total Hours Resetable Hours Lamp Strikes Total Strikes Resetable Strikes Personality Display Adjusting Display Permanent On ON OFF Display Intensity...

Page 28: ...n Tilt Moving ON OFF Colour Wheel Moving ON OFF Gobo Wheels Moving ON OFF Dimmer Curve curve1 curve 2 Default Setting Lamp On OFF On Off Test sequences Mode 1 Pan 0 255 Tilt 0 255 Zoom 0 255 Focus 0 2...

Page 29: ...lour 0 255 Gobo 0 255 Save and Reset Load Default Values 5 2 MASTER SLAVE MODE In this mode more units can be linked together as a single chain and work in a synchronized way Use a DMX cable to link t...

Page 30: ...d mode 1 255 Speed from max to min Pan Tilt time mode 1 255 Time from 0 2 s to 25 5 sec 6 4 6 6 Power Special functions 0 129 Reserved 130 139 Lamp on reset total reset except pan tilt reset 140 149 P...

Page 31: ...Amber 172 176 Blue 177 180 Orange 181 185 CTO 186 189 UV filter 190 215 Forwards rainbow effect from fast to slow 216 217 No rotation 218 243 Backwards rainbow effect from slow to fast 244 255 Reserv...

Page 32: ...33 Gobo 5 34 39 Gobo 6 40 45 Gobo 7 46 51 Gobo 8 52 57 Gobo 9 58 63 Gobo 10 64 69 Beam reducer 1 70 75 Beam reducer 2 76 81 Beam reducer 3 82 87 Beam reducer 4 Shaking gobos from slow to fast 88 95 G...

Page 33: ...Open Hole default 1 4 Hole flat field 5 7 Gobo 1 8 10 Gobo 2 11 13 Gobo 3 14 16 Gobo 4 17 19 Gobo 5 20 22 Gobo 6 23 35 Gobo 7 26 28 Gobo 8 29 31 Gobo 9 Rotation set rotation on channel 12 9 18 11 32...

Page 34: ...eserved 12 9 18 11 Rot gobo indexing and rotation Gobo indexing set position on channel 11 8 17 10 0 255 Gobo indexing Gobo rotation set position on channel 11 8 17 10 0 No rotation 1 127 Forwards gob...

Page 35: ...t position on channel 14 10 20 12 0 255 Prism indexing Prism rotation set position on channel 14 10 20 12 0 No rotation 1 127 Forwards prism rotation from fast to slow 128 129 No rotation 130 255 Back...

Page 36: ...wer 280W 64 95 Strobe effect from slow to fast 96 127 Shutter open 128 143 Opening pulse in sequences from slow to fast 144 159 Closing pulse in sequences from fast to slow 160 191 Shutter open Lamp p...

Page 37: ...acuum cleaner or an air compressor and a soft brush or a lens cloth to remove the dust deposited The lenses like any other damaged part must be replaced with original spare parts CHANGE THE LAMP Open...

Page 38: ...s Auto Sound active Master slave DMX512 Gobo wheel 1 9 rotanting gobos interchangeable with plug play system Gobo wheel 2 10 fixed gobos 4 steps beam reduce Color wheel 13 colors white Dimmer 0 100 DM...

Page 39: ...39...

Page 40: ...Proel S p A Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 Mail info proel com Web www proel com...

Reviews: