1. Warning
Before starting the unit you must read, take into consideration and comply with all the indications
described in this Manual.
This manual must be kept in a safe place, accessible to all users of the unit.
The unit must be started and handled exclusively by personnel instructed in its use and must be
employed only for the purpose for which it was designed.
Likewise, accident prevention standards, regulations, work centre directives and current legisla-
tion and restrictions must be taken into consideration at all times.
SAGOLA S.A.
, the logotypes of SAGOLA and other SAGOLA products mentioned in this manual, are
registered trademarks or brand names of the company
SAGOLA S.A.
2. Introduction
This unit belongs a the family of devices designed to spray products with compressed air with a
spray gun, providing a high level of product transfer and excellent quality finish, as well as low
levels of contamination.
The equipment consists of the following:
- Mixed Spray gun
- Cleaning brush
- Accessory wrench
- Case
3. Technical details
Net weight (swivel fitting):
550 g.
Net weight (direct fitting):
510 g.
Community directive complied with
94/9
Explosive atmosphere (Atex)
II 2G X (X)
(X) Non electric gun in explosion hazard areas (ATEX) must have the earthing connections and/or static-free feed hoses.
Maximum operating temperature from
0 to 50
o
C
Recommended working pressure not in excess of 2 bar (measured at the air inlet and recorded
in this).
Product supply pressure:
- with yellow spring: up to 120 bar
- with red spring: up to 200 bar
4. Components
1
Air nozzle
2 Trigger
3
Air inlet
4
Spring of needle
5 Spray width regulator
6 Spray gun filter
7 Tip
8 Product inlet
9 Security system
ENGLISH
1
2
6
7
4
9
5
3
8