Wear gloves when handling the product 

(see the manufacturer's recommendations) and clean the 

gun.

If, when the gun is in use, the ambient noise level exceeds 85 dB (A)

 the use of approved ear 

protectors is recommended.

The gun in itself does not propitiate any mechanical risk of perforations, impact or pinching, 

except those deriving from incorrect installations and handling.

 

While work is in progress, no vibrations are transmitted 

from the gun to any part of the body of the 

operator and reaction forces are minimal.

USE SAGOLA ANTISTATIC HOSES TO ELIMINATE POSSIBLE ELECTRICAL DISCHARGES THAT 

MIGHT CREATE THE RISK OF FIRE OR EXPLOSION.

Pay adequate attention when handling the gun in order to prevent any damage that might lead 

to dangerous situations for the user or personnel standing near the unit, as a consequence of 

leaks, breakages, etc. 

Do not use it if your mental capacity, perceptions and reactions are altered 

due to substances such as alcohol, drugs, medicines, etc., or by tiredness or for any other reason. 

The gun has been designed for use at ambient temperature. 

Its maximum service temperature is 

50°C. Although the air temperature of the compressed air or product is higher, this must not 

exceed the maximum average temperature in the body of the gun. If the temperature exceeds 

43°C, it is necessary to use personal protective equipment, such as gloves to thermally insulate 

your hands from the unit.

The use of solvents and/or detergents that contain halogenated hydrocarbons (trichloroe-

thane, methyl chloride, etc.), may cause chemical reactions in the unit as well as in its 

zinc-coated components (trichloroethane mixed with small amounts of water produces 

hydrochloric acid). For this reason, these components may rust and in extreme cases the 

chemical reaction caused may be explosive. We recommend you to use products that do 

not contain the aforementioned components. Do not use acids, soda (alkalis or pickling 

substances, etc.) for cleaning under any circumstances.

In general, 

precautions must be taken whenever the gun is handled, in order to prevent any 

damage to this.

Connectors must be securely tightened and in good condition. If pneumatic connectors are fitted, 

they must comply with the standard ISO 4414.

Safety standards must be understood and applied.

Any non-compliance with the indications set out in this manual may lead to incidents affecting the 

physical integrity of the user or other personnel or animals.

Respect and comply with indications relating to the conservation of the environment.

Always keep the safety sheets for the products to apply and the cleaning liquids to hand in case 

you need to consult them.

17. Observations

By following the instructions set out in this manual you will ensure good spraying and quality of 

finish. Should you have any doubt, please contact the 

Technical Service of SAGOLA.

Summary of Contents for 4600 Xtreme

Page 1: ...l d e i n s t r u c c i o n e s i n s t r u c t i o n m a n u a l m a n u a l d e i n s t r u e s g e b r a u c h s a n l e i t u n g l i b r e t t o d i i s t r u z i o n i m a n u e l d u t i l i s...

Page 2: ...ge 24 11 1 Clean Air 11 2 Sufficient volume of air 11 3 Adjusting Air Pressure 11 3 1 Digital Pressure Gauge Version 11 3 2 Analogue Pressure Gauge Version 11 3 3 Version without Pressure Gauge 11 4 A...

Page 3: ...ipment consists of the following _ Spray gun _ Accessory wrench _ Cleaning brush _ Instruction manual _ Case 3 Technical details Unit with product feed by gravity hereinafter the Gun with Tip and Air...

Page 4: ...onents these come into contact with aluminium stainless steel polythene and acetylene resin Do not use corrosive or abrasive products The gun has been designed for long service and can be used with th...

Page 5: ...ted Increase the amount of product correct its viscosity or use a larger fluid tip in the gun If the thickness of the layer is very thin this is due to the fact that the air pressure is excessive for...

Page 6: ...the pressure inside the pistol while there is a power supply through the battery WARNING The battery cannot be replaced in hazardous areas See Atex regulations about explosion risk areas The digital p...

Page 7: ...rning these anticlockwise See Fig 1 and Fig 2 Place the pistol on a support so that the axis of the tank is vertical Pour the product to apply into the tank Until the level is a maximum of 20 25 mm be...

Page 8: ...air hoses Should an antistatic air hose not be available you must attach the unit to a ground connection in order to eliminate any static electricity The total derivative resistance must be 100 millio...

Page 9: ...t condition IN ORDER TO OBTAIN THE BEST POSSIBLE RESULTS ALWAYS USE ORIGINAL SPARES ENSURE TOTAL INTERCHANGEABILITY SAFETY AND OPERATION 12 1 Changing the self adjusting Packing gland The needle gaske...

Page 10: ...er 12 3 Cleaning or replacement of the product filter If there is any cleaning liquid or product remaining in the tank return it to its corresponding containers To avoid any spillage keep the pistol i...

Page 11: ...U V A 02 03 18 16 28 15 13 14 12 19 20 22 10 24 23 25 11 21 21 26 10 06 08 06 07 09 29 04 17 1 2 ESP U V A 1 DVR TITANIA 2 DVR HVLP 3 DVR AQUA 4 DVR CLEAR 1 BAR 2 PSI 05 27 1 1 20 2 1 20 XL 3 1 30 4 1...

Page 12: ...ning of the gun tools and accessories used in the mixing and preparation of the product to be applied we recommend the use of SAGOLA washing machines IMPORTANT The gun can be cleaned with thinners or...

Page 13: ...eing done at that time After work has been completed thinners and the product to be applied must be returned to their corresponding storage location Keep the working area clean and free of potentially...

Page 14: ...y to use personal protective equipment such as gloves to thermally insulate your hands from the unit The use of solvents and or detergents that contain halogenated hydrocarbons trichloroe thane methyl...

Page 15: ...the case of any breakdown during the guarantee period please attach the completed warranty certificate to the unit and deliver this to the nearest Technical Assistance Service or get in touch with th...

Page 16: ...pray width regulator Dirty or damaged Tip Nozzle joint Blockages or dents in the air nozzle or fluid tip Dirty air nozzle Inadequate air pressure Inadequate amount of product Inadequate viscosity Spra...

Page 17: ...e 2014 34 UE UNE EN 60079 0 2013 A11 2014 Electric material for explosive gas environments Part 0 General requirements UNE EN 60079 11 2013 Explosive environments Part 11 Protection of the equipment f...

Page 18: ...at Kaufdatum Data de Compra Data di aacquisto E mail Sello Stamp Cachet Stempel Selo Timbro Tel Fax GUARANTEE C0NDITIONS CONDITIONS DE GARANTIE CONDICIONES DE GARANT A CONDI ES DA GARANTIA CONDIZIONI...

Page 19: ...ELLE TECHNISCHER DIENST PROFESSIONNELLE REPARATURGARANTIE SERVI O DE ASSIST NCIA T CNICA GARANT A DE REPARA AO PROFISSIONAL SERVIZIO DI ASSISTENZA TECNICA GARANZIA DI RIPARAZIONE PROFESSIONALE SAGOLA...

Reviews: