5. Warnings
· Before putting the unit into operation,
and especially after each cleaning and/or repair
operation, a check must be made that the gun
components
are securely tightened and that the
air
and/or product hoses
are airtight
(no air leaks)
. Faulty parts must be replaced or repaired as
appropriate.
·
The gun is
easy to handle
thanks to its design and the simplicity of its mechanisms.
No special
training is required
for handling the gun. Use the gun according to the
operating
,
maintenance
and
safety instructions
indicated in this manual and follow the
application methods
indicated to
obtain the required quality of finish.
· Before putting the unit into operation,
we recommend you to
clean the gun
as this has been
subjected to functional tests and before packaging it is treated internally with a protective coating,
some of which may still remain. Apply thinner to eliminate this. Remove any residual grease
applied during assembly.
· Ensure that the products to be applied are chemically compatible with the components these
come into contact
with (aluminium, stainless steel, polythene and acetylene resin).
· Do not use corrosive or abrasive products.
The gun has been designed for long service and can be used with the majority of the products
available on the market.
Its use with highly aggressive products will quickly increase the need for
maintenance and spares. If you need to apply special products, please contact SAGOLA S.A.
· Read and apply all the
information, instructions and safety measures indicated by the manufac-
turer of the products to be applied (thinners, etc.) as these may provoke chemical reactions, fires
and/or explosions, or be toxic, irritant or harmful and in all cases dangerous for the health and
personal safety of the user and of other persons nearby
(see chapter on Safety and Health).
·
Mix, prepare and filter the product to be applied
in accordance with the manufacturer's
ENGLISH
20/21
1
2
10
14
4
3
5
6
13
12
11
7
8
9
4. Components
1
Air nozzle
2
Head packing gland
3
Trigger
4
Valve packing gland
5
Digital pressure gauge access plug
6
Air inlet
7
Air valve
8
Product regulator
9
Spray width regulator
10 Product filter
11 Non drip plug
12 Pressure gauge sight glass
13 Air flow regulator
14 Product Cup