- Place the compressor on a horizontal and non 

sliding surface in order to avoid vibrations and 

movements.
- Install the compressor in a cool and well ventila-

ted area and with a temperature between 5 and 

40°C. Check that the voltage and frequency are 

compatible with the compressor, check the plug 

has a correct   ground connection.
- Before connecting the compressor, check that 

the mains voltage is adjusted to the electrical 

characteristics of the compressor.

- Observe and apply current standards and 

directives.
- In the CP2000 model, to preserve its durability, 

use rationally the switch in position II.
- Never leave the compressor exposed to dust, 

acids, vapors, flammable or explosive gases or 

elements (rain, sun, fog, snow).

1. With the electric socket disconnected, 

connect the air hose to compressor and 

airbrush.
2. Check that the compressor is totally depressu-

rized. Press the airbrush outlet valve and verify 

no air is coming out.
3. Connect the electric socket, check that the 

pressure regulator is closed, and turn on the start 

switch.

In the 

CP 1000

, the compressor starts when there 

is an air pressure less than 3 bars inside the 

tank, and stops automatically when it reaches 4 

bars. When the tank is full (approx. 100 

seconds), turn the pressure regulator until the 

pressure gauge indicates the desired working 

pressure.

In  the 

CP 2000

 model with the switch in position 

1 the compressor starts when there is an air 

pressure less than 3 bars inside the tank, and 

stops automatically when it reaches 4 bars 

(approx. 60 seconds). When the tank is full, turn 

the pressure regulator until the pressure gauge 

indicates the desired working pressure.
With the switch in position 2 the compressor is 

running continuously generating a maximum 

pressure of 6 bars (tank loaded about 180 

seconds).

IMPORTANT:

Before start working, check for air leaks. 
With the pressure gauge set at the desired 
pressure, turn the switch off and check that 
the pressure in the gauge is fixed. If the 
pressure goes down quickly, it means there 
is an air leak. Any small leak will affect the 
correct working of the compressor and the 
job quality.

- 16 -

5. START UP

4. ADVICE

Summary of Contents for CP1000

Page 1: ...m a n u a l d e i n s t r u c c i o n e s i n s t r u c t i o n m a n u a l Compresor Compressor...

Page 2: ......

Page 3: ...t cnicos p g 5 4 Consejos p g 6 5 Puesta en marcha p g 6 6 Mantenimiento p g 7 7 Limpieza p g 7 8 Seguridad p g 7 9 Importante p g 7 10 Lista de recambios p g 8 11 Lista de accesorios p g 9 12 Condici...

Page 4: ...imismo deber tener en cuenta las Normas de Prevenci n de accidentes los Reglamentos y Directivas para los Centros de trabajo y las Leyes y restricciones vigentes SAGOLA S A los logotipos de SAGOLA y o...

Page 5: ...de 3 litros Potencia 1 6 HP Velocidad 1 450 1 700 r p m Caudal de aire 20 23 L min Autoarranque a menos de 3 bar 43 psi Parada autom tica a 4 bar 57 psi Regulador de presi n 0 6 bar 86 psi Nivel sonor...

Page 6: ...el compresor permanece en marcha continuamente generan do una presi n m xima de 6 bares aprox 180 segundos Sit e el compresor sobre una superficie antideslizante horizontal y uniforme para evitar desl...

Page 7: ...s l mparas etc Revisar temperaturas Utilice equipos respiratorios homologados gafas protectoras y protectores ac sticos as como mangueras antiest ticas El equipo no propicia riesgos mec nicos si se ut...

Page 8: ...8 10 LISTA DE RECAMBIOS 01 04 07 08 09 10 11 12 14 13 15 05 16 17 18 19 05 06 03 02 21 20 1 220 V 2 110 V 1 220 V 50Hz 2 110 V 60Hz 1 220 V 2 110 V...

Page 9: ...9 10 LISTA DE RECAMBIOS 03 1 220V 50Hz 2 110V 60Hz 1 220V 50Hz 2 110V 60Hz 21 12 17 10 14 13 13 05 05 11 20 04 16 01 27 15 02 02 25 26 18 28 19 24 23 09 09 14 10 1 220 V 2 110 V...

Page 10: ...odo de GARANT A adjunte al aparato el justificante del certificado de garant a y entr guelo en el Servicio de Asistencia que m s le interese o bien p ngase en contacto con f brica Queda excluida cualq...

Page 11: ...y a las disposiciones seg n el ordenamiento legislativo nacional del pa s de destino Es conforme a los requisitos de las siguientes Directivas Europeas y de haber utilizado para su construcci n las s...

Page 12: ......

Page 13: ...l data page 15 4 Advices page 16 5 Start up page 16 6 Maintenance page 17 7 Cleaning page 17 8 Security page 17 9 Important page 17 10 Part list page 18 11 List of accessories page 19 12 Conditions of...

Page 14: ...Standards Regulations Work Centre Directives and current legislation and restrictions must be taken into consideration SAGOLA S A the SAGOLA logotypes and other SAGOLA products mentioned in this manua...

Page 15: ...50 1700 r p m Air outlet 20 23 L min Electrical switch Auto start with less than 3 bar 43 psi Auto stop at 4 bar 57 psi Pressure Regulator 0 6 bar 86 psi Noise level 47 dB Double piston compressor wit...

Page 16: ...that the pressure regulator is closed and turn on the start switch In the CP 1000 the compressor starts when there is an air pressure less than 3 bars inside the tank and stops automatically when it...

Page 17: ...ps etc Check temperatures Use approved breathing equipment goggles and ear protectors The unit does not cause mechanical hazards if used correctly It does not transmit vibrations Not applying the indi...

Page 18: ...18 10 PART LIST 01 04 07 08 09 10 11 12 14 13 15 05 16 17 18 19 05 06 03 02 21 20 1 220 V 2 110 V 1 220 V 50Hz 2 110 V 60Hz 1 220 V 2 110 V...

Page 19: ...19 10 PART LIST 03 1 220V 50Hz 2 110V 60Hz 1 220V 50Hz 2 110V 60Hz 21 12 17 10 14 13 13 05 05 11 20 04 16 01 27 15 02 02 25 26 18 28 19 24 23 09 09 14 10 1 220 V 2 110 V...

Page 20: ...Fax 34 945 214 147 In the case of any malfunction during the peiod of GUARANTEE enclose the guarantee certifica te with the apparatus and deliver it to the nearest Technical Service or get in contact...

Page 21: ...dates and provisions according to the national legislative code of the destination country Is in conformity with the requirements of the following European Directives and has used the following techni...

Page 22: ......

Page 23: ...at Kaufdatum Data de Compra Data di aacquisto E mail Tel Fax Sello Stamp Cachet Stempel Selo Timbro GUARANTEE C0NDITIONS CONDITIONS DE GARANTIE CONDICIONES DE GARANT A CONDI ES DA GARANTIA CONDIZIONI...

Page 24: ...RATION PROFESSIONNELLE TECHNISCHER DIENST PROFESSIONNELLE REPARATURGARANTIE SERVI O DE ASSIST NCIA T CNICA GARANT A DE REPARA AO PROFISSIONAL SERVIZIO DI ASSISTENZA TECNICA GARANZIA DI RIPARAZIONE PRO...

Reviews: