background image

Waterproof Scale Operation Instruction

4

7. High performance in A/D converter

Sample rate: up to 40 times / second

Internal resolution: 600,000

External resolution: 1/1000 ~ 1/30000

Non-linearity: < 0.016% of full scale

Input range of load cell: 0 ~ 16mv

Load cell excitation: + DC5V

8. Waterproof design

Waterproof rubber button;

Waterproof adapter

All sealing PCB design

Waterproof load-cell.

3.2 POWER SUPPLY

1. Power source: Waterproof adapter AC 110~220V / 50Hz, DC 12V / 500ma
2. Rechargeable battery: DC 6V / 4Ah ( Option )

3.3 LOW BATTERY WARNING

Please note when battery capacity indication is displayed shortly on the display , the internal battery

needs to be recharged. The scale will power off automatically without recharging after the low battery
symbol shows upon for 20 to 30 hours on the display. As a recommendation, the scale should be fully
recharged before using the scale again.

3.4 SPECIFICATIONS

Model

KW1000G-3

KW1000G-6

KW1000G-15

KW1000G-30

Capacity

3kg x 0.5g

6kg x 1g

15kg x 2g

30kg x 5g

Max. Tare

3kg

6kg

15kg

30kg

Resolution

1/3000~1/30000

Platter size

230 x 185mm

Display

6 digits Green LED display

Rated Voltage

AC\DC 100~240V ; 6V/4Ah Rechargeable battery

Temp. range

0

~ 40

IP protection

IP68

Humidity

≤100% RHM

Dimension

260 x 245 x 110mm

Gross weight

4.5 KG

Carton packing

Single packing / 4pcs each carton

Summary of Contents for KW1000G-3

Page 1: ...Waterproof Scale Operation Instruction 1 WATERPROOF SCALE Operation Instruction Ver1 0...

Page 2: ...PREPARING TO USE THE SCALE 1 III INTRODUCTION 1 IV LCD DISPLAY SYMBOLS 2 V KEYBOARD FUNCTION 3 VI GENERAL PARAMETER 4 VII CONNECTION OF INTERFACE 6 VIII MEANS OF POWER SUPPLY CHARGING 7 IX COUNTING F...

Page 3: ...our leveling feet to set the level of scale platform 3 Avoid operating the scale in direct sunlight or drafts of any kind 4 Take away any weight that might be on the platform before the scale is switc...

Page 4: ...pacity indication is displayed shortly on the display the internal battery needs to be recharged The scale will power off automatically without recharging after the low battery symbol shows upon for 2...

Page 5: ...Capacity Shining is charging Kg lb lb oz g PCS Weighing unit HI OK LO Checking weighing Front panel Keyboard V KEYBOARD FUNCTION KEYS DESCRIPTIONS Turn on off The indicator will be turned on when pre...

Page 6: ...ANDBY MODE Set Pr AB It is parameter of LED display is closed for saving power A for Standby mode B for the effective time A 0 means LED is lighted all the time A 1 means Only STB indication is lighte...

Page 7: ...n is working X 0 means the indicator will keep checking and alert even if the reading is unstable X 1 means the indicator will alert after the reading is stable X 2 9 means the indicator will alert wh...

Page 8: ...MODE enter counting mode and it displays n XXXXX Step 3 Press key to input the sample number and it displays n 00100 Step 4 Press MODE to confirm and upload the sample unit Step 5 Loading the weight s...

Page 9: ...ODE to confirm and enter into the next step Step 3 Display Resolution The screen displays XXXXX The value shown is the display resolution Display resolution division kg full capacity kg Example take 0...

Page 10: ...able 4 X 3 Indicator will send out 1 data after the weighing is stable Press to select the value and press MODE to confirm and finish to set the Serial protocol Step 6 Weight response speed Filtering...

Page 11: ...RROR SIGNAL There will shows error signal when the scale have some problem Error 1 means calibration isn t workable weight is too light or division is too high Error 2 means wrong zero check the load...

Reviews: