Waterproof Scale Operation Instruction
7
if scale is under this weight, “ LO ” indication is shinning with alert buzzer.
Press
[►] & [▲]
key to set the point weight, then press
[ MODE ]
to confirm and finish.
For example:
For one 30kg scale, desired weight is 10kg, deviation value is ±0.2kg.
Step 1: Pressing
[►] & [▲]
key to set the point weight “10.20kg”, the screen will display 10.20 kg
and “
HI
” indication is shinning, , then press
[ MODE ]
to confirm and next to Step 2..
Step 2: Pressing
[►] & [▲]
key to set the lowest weight 9.80kg, the screen will display 9.80 kg
,
“ LO ” indication is shinning,then press
[ MODE ]
to confirm and next step.
Step 3: After back to normal weighing, load the goods in scale, if over or under this two points weight,
the
“HI”
or
“LO”
indication will be shinning with alert buzz to annunciate to user. But the
weight is in the range of setting, the “OK” indication will shows without alert buzz.
6.5. SET OF EFFECTIVE TERM IN CHECK WEIGHING MODE
Set “ SPt X”. It is parameter of the effective term of check weighing mode. It only works when
the check weighing function is working.
X=0, means the indicator will keep checking and alert, even if the reading is unstable.
X=1, means the indicator will alert after the reading is stable.
X=2~9, means the indicator will alert when the reading appear same times that preset the number .It
happens in reading is unstable.
Press
[▲]
key to select and press
[ MODE ]
to confirm and next step.
6.6. SETTING OF AUTO SHUTDOWN PROTECTION FOR LOW BATTERY
Set “ PLo X”.It is parameter of Auto shutdown protection function.
It displays
PLO XX
.
“XX”
means the lowest percentage of battery capacity. When the capacity
of battery is lower than the setting value, the indicator will be shutdown and need to be charged. It is very
helpfully to increase the life of battery.
Press
[▲]
key to select from
“0~40”
and press
[MODE]
to confirm and exit to weighing mode.
XII. SETTING OF WEIGH UNIT
Press and hold
[MODE]
key for 3 seconds, the screen will display Unit = X . It is the menu of unit
weigh setting. X is from 0-4 for 5 kinds of unit weigh.
0 =g, 1= kg, 2 = lb, 3= lb.oz, 4= PCS
Press
[▲]
key to select and press
[MODE]
to confirm and exit to weighing mode.
XIII. COUNTING FUNCTION OPERATION
Attention:
In counting mode, the scale isn’t allowed for weight unit switching function. The function
must be set in
Step