Waterproof Scale Operation Instruction
9
Step 8:
Offload the weight, reading “0.00kg ” will display and Zero indication will show denoting
there is nothing being weighted on the scale.
Step 9:
The scale will return to weighing mode after calibration is finished.
Attention: Do remember to switch the breaker into “OFF” position and seal the cover again..
X. CONFIGURATION SETTINGS
Open up the cover of Calibration key before setting, switch the breaker into “ON” .
Step 1: Enter Setup
Press and hold
[MODE]
and
[TARE]
for 3 seconds together, after it shows
“
= = = = = =
”
then
release the buttons, it will display
“ CAL SP ”
.
Press
[MODE]
to enter into setup mode and
“- SET - ”
will display. Press[ ►] to enter sub menu.
Step 2: Reading division
The screen displays
“d XXXX ”
. It means to choose the reading division.
Example:
For a 60kg scale, if “d” is set to 0.02kg, the scale will show a division of 0.02kg among
0kg~60kg.
Press
[►] & [▲]
key to change the values.
Press
[MODE]
to confirm and enter into the next step.
Step 3: Display Resolution
The screen displays
“ XXXXX”
. The value shown is the display resolution.
Display resolution = (division) kg/ (full capacity) kg
Example: take “ 06000” as 6000, take “ 12000” as 12000.
Press
[►] & [▲]
key to change the value of the selected digit.
Press
[MODE]
to confirm value and enter in to the next step.
Note: Please calibrate the scale again after changing ‘Division’ and ‘Display Resolution’ settings.
Step 4: Zero range / Zero tracking / Zero display range
The screen displays
“Ut ABC”
.
A: Zero range when power on, 1~9 mean 10%~90% FS to zero, 0 mean not to zero
B: Zero tracking range, 0~9 means 1~9 x 0.25d for tracking range.
C: Zero display range. 0~9 means the display keep shows zero even the inner display from 0~9d
Press
[►] & [▲]
key to change the value of the selected digit.
Press
[MODE]
to confirm value and enter in to the next step.
Step 5:
Setting RS-232 Serial protocol
The screen displays
rS-0 . Press [MODE] to ignore the setting if no need, and enter next step.
5-1. Baud rate
Press
[►]
will display
“bo. XXXX”.
Press
[▲]
to select from 1200,2400,4800,9600,11400 and press [MODE] to confirm.