Lewmar V-700 Windlass Troubleshooting Chart
Failure to Operate Troubleshoot Chart: Reversing Toggle Control Switch
(Part No. 0052519)
Is there voltage at the input terminal (positive) to the
control switch?
If no voltage is present, the battery isolation is OFF, the
breaker is tripped or a fuse has blown. The battery may also
have been dead or disconnected.
Yes
q
No
u
Check voltage at the output terminals of the control
switch with the switch on forward then reverse.
Control switch is defective.
Yes
q
No
u
Replace Motor
Sluggish Operation Troubleshoot Chart
Is windlass overloaded?
Ease the load and ensure the battery is well charged.
Yes
q
No
u
Check the voltage across the motor leads with the
windlass on. (Proper voltage is 13.5V. Constant low
voltage will destroy the motor).
Is the voltage low? (Below 11.0V on a 12V system?
There is a severe voltage drop in the circuit.
Check for undersized cables, poor connections or corroded
connections. Also check for resistance across the battery
isolation switch or solenoid. (Feel them to see if they are
heating up).
Yes
q
No
u
Is the voltage correct? (Above 11.0V and anchor is
not fouled).
The motor is defective. Replace the motor.
Yes
q
No
u