B.6 Separate ground cable
B.6.1 Ground cable - construction
When dealing with electrical installations in a marine
environment, all wiring must be done with double insulated,
tinned strands, high quality and if exposed also UV resistant
cables. This shall also apply to the separate ground cable
mentioned in the previous paragraphs.
The ground cable is constructed using an appropriate cable
with a cross section area of at least 6 mm
2
(AWG10) and
terminated with insulated ring crimp terminals – see
illustration below. The crimp terminals must be a marine
approved type e.g. the DuraSeal series from Raychem.
Figure B-6: Separate ground cable