Installation of the ADU
98-136280-B
Chapter 3: Installation
3-19
3333
In
stall
ati
o
n
Select a suitable size for the cable gland: 16—20 mm diameter or 19—23 mm
diameter. See also
N-connector interface on the ADU
detailed drawing how to connect the N-connector on the ADU.
Ensure that the connector assembly is properly protected against seawater and
corrosion. As a minimum, wrap it with self-amalgamating rubber.
9. Put the protection plate in place and fasten the 4 bolts (picture 5).
10. Fasten the nut (picture 6).
Where the cables are exposed to mechanical wear — on deck, through bulkheads, etc.
— protect the cables with steel pipes. Otherwise, follow standard procedures for cabling
in ship installations.
Figure 3-17: Connecting the ADU cable
Protection plate
N connector
1
2
3
4
5
6
SAILOR100IM.book Page 19 Friday, January 18, 2013 10:28 AM