Removal and replacement of ADU modules
8-32
Chapter 8: Service & maintenance
98-137654-A
8.5.6 Replacing motor and encoder
The ADU is equipped with three (3) DC-motors, two of which are
identical, and one (1) step motor, for the axes:
• Elevation (DC motor).
• Azimuth (DC motor).
• Cross Elevation (DC motor).
• Polarisation motor (step motor).
The DC-motors are all brush less motors, controlled by their
individual DDM. The step motor is controlled by its PMM. To each of
the DC-motors and step motor a corresponding encoder provides
feedback of its position.
For step-by-step instructions see:
Removing the Elevation Motor and Encoder
Inserting a new Elevation Motor and Encoder
Inserting a new Azimuth Encoder
Removing the X Elevation Motor and Encoder
Inserting a new X Elevation Motor and Encoder
Removing the Polarisation Motor
Inserting a new Polarisation Motor
Figure 8-31: Motors and encoders
Polarisation encoder
Polarisation
motor
Azimuth encoder
Azimuth motor
Elevation
motor & encoder
X elevation
motor & encoder
SAILOR100TM.book Page 32 Tuesday, January 29, 2013 2:44 PM
Summary of Contents for 100
Page 1: ...TRAINING INSTALLATION SERVICE MANUAL SAILOR 100 Satellite TV ...
Page 2: ......
Page 13: ...Table of contents 98 137654 A xi SAILOR100TM book Page xi Tuesday January 29 2013 2 44 PM ...
Page 14: ...Table of contents xii 98 137654 A SAILOR100TM book Page xii Tuesday January 29 2013 2 44 PM ...
Page 215: ...Appendices SAILOR100TM book Page 1 Tuesday January 29 2013 2 44 PM ...
Page 216: ...SAILOR100TM book Page 2 Tuesday January 29 2013 2 44 PM ...
Page 254: ...Glossary Glossary 4 98 137654 A SAILOR100TM book Page 4 Tuesday January 29 2013 2 44 PM ...
Page 261: ......